NEW PRODUCTS,Size reduction in comparison,to the conventional model TJ type. The TQ 5 5 type is 1 mm lower than,TJ 5 5 and the TQ 8 14 types are lower. than TJ 14 which enables more efficient,use of available space. SPECIFICATIONS RATING PERFORMANCE STANDARD OPERATING CONDITION. Conformable standard JIS C2811,Item TQ 5 5 TQ 8 TQ 14. Rated insulation voltage Ui 600V AC DC,Rated impulse withstand voltage 6 000V.
Rated current carring capacity Ith 30A 40A 60A, Applicable wire size 2 to 5 5mm2 3 5 to 8mm2 5 5 to 14mm2. Screw size M4 8 5 M5 11, Applicable crimp terminal R2 4 R3 5 4 R5 5 4 R3 5 5 R5 5 5 R8 5 R5 5 5 R8 5 R14 5. Performance, Power frequency withstand voltage 2 500 V AC for 1 minute. Impulse withstand voltage 7 200 V three times for each pole 1 2 50 s. Standard Ambient temperature 20 to 50 C,operating Storing temperature 40 to 85 C. condition Altitude 2 000m max, The dropping off prevention rib is effective for wires 8 mm2 or larger in size.
TYPE CODING,TQ 5 5 R 36 XD,No Item Code Description Remarks. TQ 5 5 5 5 Unit thickness 11mm, Basic type TQ 8 Applicable wire 8 Unit thickness 14mm. TQ 14 mm2 14 Unit thickness 14mm,None Gray Munsell approximate value 7 5BG4 1 5. Unit color,R Red Munsell approximate value 7 5R4 5 14. 1 to the TQ 5 5 1 to 50 Maximum number of units depends on the number of units mounted. No of units maximum TQ 8 1 to 39 on a rail of up to 600 mm If the mounting range exceeds 600 mm it depends on. TQ 14 the maximum number of units mounted on the TKB D rail of up to 1 000 mm. number 1 to 39, XD TXB D rail Punched rail Recommended maximum length 600mm.
Rail designation XF TXB F rail U cut rail Recommended maximum length 600mm. KD TKB D rail Punched reinforced rail Recommended maximum length 1 000mm. STANDARD PRODUCTS,Applicable wire,2 to 5 5mm2 38 11 Applicable crimp terminal. 1 5 Accessories,1 5 End plate TQE 5 5A B,Standard marker strip TUM 2 0 5T. Standard rail TXB,End clamp TXL,Red terminal type is also available TQ 5 5R. Cover TUC 3,Applicable wire 45 14,3 5 to 8mm2 23 12 6. Applicable crimp terminal,2 5 Accessories,End plate TQE 8A B.
Standard marker strip TUM 2 0 5T,Standard rail TXB. End clamp TXL,Red terminal type is also available TQ 8R. Cover TUC 6,Applicable wire 45 14,Applicable crimp terminal. 5 5 to 14mm2 23 12 6,1 Accessories,End plate TQE 14A B. Standard marker strip TUM 2 0 5T,Standard rail TXB.
End clamp TXL,Red terminal type is also available TQ 14R. Cover TUC 6,NEW PRODUCTS,DIMENSIONS Combination,Rail TXB D 12 5 12 5 12 5 Rail TXB F. P Mounting pitch 9 7,L 5 11 11 5,Assembly dimensions Typical P Mounting pitch. Number of units 1 5 10 15 20 L,A 21 65 120 175 230. TXB F P 50 90 145 200 255,rail L 60 100 155 210 265.
TXB D P 40 100 140 200 260,rail L 57 117 157 217 277. Number of units 25 30 35 40 45 50,A 285 340 395 450 505 560. TXB F P 310 365 420 475 530 585,rail L 320 375 430 485 540 595. TXB D P 320 360 420 480 540 580,rail L 337 377 437 497 557 597. TQ 8 TQ 14,TQ 8 and TQ 14 are the same size except for ribs.
Rail TXB D 12 5 12 5 12 5 Rail TXB F,P Mounting pitch 7 4. P Mounting pitch,Assembly dimensions Typical,Number of units. A TQ 14 10 6,Number of units,The above figure shows TQ 8 dimensions. TABLE OF ASSEMBLED DIMENSIONS,Assembly on TXB D type Assembly on TXB F type. P L 17 P L 10,Type TQ 5 5 TQ 8 14 Type TQ 5 5 TQ 8 14.
No of units P L Rail designation P L Rail designation No of units P L Rail designation P L Rail designation. 1 40 57 XD 3 60 77 XD 4 1 50 60 50 60 XF 60,2 60 77 XD 4 60 77 XD 4 2 60 70 65 75 XF 75. 3 80 97 XD 5 80 97 XD 5 3 70 80 80 90 XF 90,4 80 97 XD 5 100 117 XD 6 4 80 90 95 105 XF 105. 5 100 117 XD 6 100 117 XD 6 5 90 100 105 115 XF 115. 6 100 117 XD 6 120 137 XD 7 6 105 115 120 130 XF 130. 7 120 137 XD 7 140 157 XD 8 7 115 125 135 145 XF 145. 8 120 137 XD 7 140 157 XD 8 8 125 135 150 160 XF 160. 9 140 157 XD 8 160 177 XD 9 9 135 145 165 175 XF 175. 10 140 157 XD 8 180 197 XD 10 10 145 155 175 185 XF 185. 11 160 177 XD 9 200 217 XD 11 11 160 170 190 200 XF 200. 12 160 177 XD 9 200 217 XD 11 12 170 180 205 215 XF 215. 13 180 197 XD 10 220 237 XD 12 13 180 190 220 230 XF 230. 14 200 217 XD 11 240 257 XD 13 14 190 200 235 245 XF 245. 15 200 217 XD 11 240 257 XD 13 15 200 210 245 255 XF 255. 16 220 237 XD 12 260 277 XD 14 16 215 225 260 270 XF 270. 17 220 237 XD 12 280 297 XD 15 17 225 235 275 285 XF 285. 18 240 257 XD 13 280 297 XD 15 18 235 245 290 300 XF 300. 19 240 257 XD 13 300 317 XD 16 19 245 255 305 315 XF 315. 20 260 277 XD 14 320 337 XD 17 20 255 265 315 325 XF 325. 21 260 277 XD 14 340 357 XD 18 21 270 280 330 340 XF 340. 22 280 297 XD 15 340 357 XD 18 22 280 290 345 355 XF 355. 23 300 317 XD 16 360 377 XD 19 23 290 300 360 370 XF 370. 24 300 317 XD 16 380 397 XD 20 24 300 310 375 385 XF 385. 25 320 337 XD 17 380 397 XD 20 25 310 320 385 395 XF 395. 26 320 337 XD 17 400 417 XD 21 26 325 335 400 410 XF 410. 27 340 357 XD 18 420 437 XD 22 27 335 345 415 425 XF 425. 28 340 357 XD 18 420 437 XD 22 28 345 355 430 440 XF 440. 29 360 377 XD 19 440 457 XD 23 29 365 375 445 455 XF 455. 30 360 377 XD 19 460 477 XD 24 30 365 375 455 465 XF 465. 31 380 397 XD 20 480 497 XD 25 31 380 390 470 480 XF 480. 32 380 397 XD 20 480 497 XD 25 32 390 400 485 495 XF 495. 33 400 417 XD 21 500 517 XD 26 33 400 410 500 510 XF 510. 34 420 437 XD 22 520 537 XD 27 34 410 420 515 525 XF 525. 35 420 437 XD 22 520 537 XD 27 35 420 430 525 535 XF 535. 36 440 457 XD 23 540 557 XD 28 36 435 445 540 550 XF 550. 37 440 457 XD 23 560 577 XD 29 37 445 455 555 565 XF 565. 38 460 477 XD 24 560 577 XD 29 38 455 465 570 580 XF 580. 39 460 477 XD 24 580 597 XD 30 39 465 475 585 595 XF 595. 40 480 497 XD 25 40 475 485,41 480 497 XD 25 41 490 500. 42 500 517 XD 26 42 500 510,43 520 537 XD 27 43 510 520. 44 520 537 XD 27 44 520 530,45 540 557 XD 28 45 530 540.
46 540 557 XD 28 46 545 555,47 560 577 XD 29 47 555 565. 48 560 577 XD 29 48 565 575,49 580 597 XD 30 49 575 585. 50 580 597 XD 30 50 585 595,NEW PRODUCTS,ACCESSORIES. Applicable accessories, End plate Marker strip Marker strip case Marker sheet Aluminum rail applicable Aluminum rail semi applicable. Accessories,TQ 5 5 TJ 5 5 mark sheet,TQE 8 A TUM marker TXB TKB.
TQ 8 TUM 2 0 5T TJ 14 mark sheet, TQE 8 B strip case 10 Standard DIN rail Reinforced DIN rail. TQ 14 TJ 14 mark sheet, End clamp applicable End clamp semi applicable Cover Jumper Remarks. Accessories, SB11 without insulation coat Jumper indicates the number of poles. TQ 5 5 TUC 3,SB11CB with insulation coat 2P 3P 4P 5P 12P. TQ 8 SB14 without insulation coat Jumper indicates the number of poles. TQ 14 SB14CB with insulation coat 2P 3P 4P 5P 12P,TQE A TQE B.
B B Type mane TQE 5 5A TQE 8A TQE 14A,Dimension TQE 5 5B TQE 8B TQE 14B. A A A 33 38 38,B 40 45 45, Marker strip Order unit 100 Marker strip case Order unit 100. TUM 2 0 5T TUM marker strip case 10,Plate thickness 0 3 mm. 10 Plate thickness 0 5mm Transparent case,Marker sheet Order unit 100. Type name TJ 5 5 TJ 14,marker sheet marker sheet,Pitch 11 14.
Aluminum rail, TXB Standard DIN rail Order unit 50 TKB Reinforced DIN rail Order unit 20. End clamp Order unit 100 Cover Order unit 20,TXL applicable TJL semi applicable TUC. 12 5 46 Type name TUC 3 TUC 6,46 Dimension,B 1000 1000. NEW PRODUCTS,Jumper Order unit 10,SB11CB SB14CB, Without insulation coat SB 11 Without insulation coat SB14. With insulation coat black SB 11 C B With insulation coat black SB14CB. dimensions dimensions,No of units 2 3 4 5 12 No of units 2 3 4 5 12.
L 20 5 31 5 42 5 53 5 130 5 L 26 40 54 68 166,NP mount Order unit 50. TX NP mount S TX NP lens Set of TX NP mount S and lens. NP mount that can be attached to TXL end clamp,ACCESSORIES FOR TEST TOOLS. Remover Order unit 1 Plug Order unit 100,MIC NQ XC P1 B. Used to pull out a receptacle from the XC plug 12 5. Push Raise Pull out the lead wire 8 27 5,Receptacle contactor Order unit 100. MIC Mark II manufactured by AMP, Refer to the IS 259J 91592 1 and IS 260J 755400 1 Applicable wire Insulation Model of receptacle Instruction.
Material and finish, crimping tool instruction manuals supplied by AMP mm2 coat size Tape Loose piece manual for tool. Brass Tin plated 172775 1 172776 1, 0 3 to 0 89 1 5 to 2 6 Brass Partial gold plated 172775 2 172776 2 91592 1. Phosphor bronze Tin plated 172775 4 172776 4,Brass Tin plated 172773 1 172774 1. 0 5 to 2 27 2 1 to 3 4 Brass Partial gold plated 172773 2 172774 2 755400 1. Phosphor bronze Tin plated 172773 4 172774 4,WIRE DROPPING OFF PREVENTION FUNCTION. Example of trouble, With conventional models the terminal screw can be tightened even if the screw is not inserted in.
the screw hole of the crimp terminal See 1 In particular when two wires are connected a loose. connection is difficult to detect in a visual inspection if the lower terminal is pinched by the screw. Front 1 Terminal position that causes pinching,Terminal screw. Oblique view,When a single wire,is connected the Spring washer. crimp terminal is Washer,pinched by the terminal,screw This condition can Crimp terminal. be visually detected from,the front However if the. terminal is located at the Wire,back the loose Conductive metal.
connection may be,difficult to detect Front,when obliquely. viewed Back,Front view,When two wires are connected. only the lower terminal is pinched,by the screw This condition is very. difficult to detect visually from the,Countermeasure. The guide ribs lead the crimp terminal to the proper position See 2 2 Normal position. This structure prevents the crimp terminal from being pinched by the Terminal screw. terminal screw because the terminal cannot be located at a position that. causes pinching when the screw is tightened,Spring washer.
Crimp terminal,Conductive metal,Ribs are provided on both sides of. the unit The crimp terminal can,be inserted only between the ribs. If the terminal is located at an,improper position the wire is. raised and the loose,connection can be easily,The terminal block with the wire. dropping off prevention function is gray,NEW PRODUCTS.
APPLICABLE TO TEST TOOLS,Quick connection,Inspection time reduction. Wire dropping off Withstand voltage test,Quick connection possible. prevention Sequence test,up screw type Jumper plug. Assembly time reduction,The wire dropping off prevention. Marker strip attached,function greatly reduces wiring time.
Inspection time reduction,When the TJ CH socket for tests is. TQ type Socket, terminal for tests attached in factory test efficiency can. block be improved,Wires are supplied separately, TJX 5 5CH 12P Exclusive for 12 poles TJ 5 5CH No of poles PC Joint type. 15 poles max,XC P1 B Receptacle,For TQ 5 5 For TQ 5 5. TJ 14CH No of poles PC Joint type,15 poles max,For TQ 8 TQ 14.
The TQ type terminal blocks are available in three types TQ 5 5 TQ 8 and TQ 14 covering cable sizes of 2 to 14 mm2 Unit color differentiation The terminal block is gray It can be easily differentiated from conventional black terminal blocks The TQ type uses high performance engineering plastic

Related Books