Thermo Scientific Furnaces

Thermo Scientific Furnaces-Free PDF

  • Date:25 Jan 2020
  • Views:39
  • Downloads:0
  • Pages:18
  • Size:1.76 MB

Share Pdf : Thermo Scientific Furnaces

Download and Preview : Thermo Scientific Furnaces


Report CopyRight/DMCA Form For : Thermo Scientific Furnaces


Transcription:

Thermo Scientific furnaces, Furnaces in laboratory and industrial settings are used every day for a wide variety of simple and. technical applications Deliver consistent results with a furnace you can depend on to attain your daily. goals Choose from a wide offering to accommodate your applications needs which may include. Research for example material science, ceramic metal glass environmental agriculture food chemistry. Metal treatment,Water treatment,Electronics, Designed with safety in mind Thermo Scientific furnaces offer temperature ranges up to 1200 C. temperature control options to meet your application needs embedded or open heating elements. designed to keep samples safe while maintaining reliable temperature uniformity. Types of furnaces 4 5,Features controllers and programmers 6 7. Thermo Scientific box furnaces,Thermolyne small benchtop muffle furnaces 8.
Thermolyne industrial benchtop muffle furnaces 9,Thermolyne benchtop muffle furnaces 10 12. Thermolyne premium large muffle furnaces 13,Thermolyne largest tabletop muffle furnaces 14. Thermolyne atmosphere controlled ashing furnaces 15. M104 muffle furnaces 16,K114 chamber furnaces 17,M110 muffle furnaces 18. Lindberg Blue M Moldatherm box furnaces 20,Lindberg Blue M LGO box furnaces 21 22. Lindberg Blue M 1200 C heavy duty box furnaces 23, Lindberg Blue M 1500 C heavy duty box furnaces independent control 24.
Lindberg Blue M 1500 C box furnace controllers 25, Lindberg Blue M multipurpose 1500 C box furnaces 26. Lindberg Blue M 1700 C box furnaces large chamber integral control 27. Lindberg Blue M 1700 C box furnaces independent control 28. Thermo Scientific tube furnaces,Lindberg Blue M mini mite tube furnaces 29. Lindberg Blue M 1100 C tube furnaces three zones 30. Lindberg Blue M 1200 C split hinge tube furnaces and controllers 31 32. Lindberg Blue M 1500 C general purpose tube furnaces 33. Lindberg Blue M 1700 C tube furnaces 34,Thermo Scientific Crucible Furnaces. Lindberg Blue M 1200 C crucible furnace top loading 35. Temperature consistency and,sample safety for your laboratory and. industrial applications,For over 55 years we have offered a variety of.
feature rich furnaces to an array of industries and Box furnaces. verticals to accommodate ordinary and technical, tasks alike ypically used for processing larger samples or to. easily place and access samples We offer a versatile. selection of small medium and large box furnaces, suitable for a variety of industrial and laboratory. applications Advanced engineering and specialized,construction techniques include variable density. insulation double shell cabinets long life heating. elements and side swing doors vertical or horizontal. or swing down doors,Lindberg Blue M heavy duty 1200 C. box furnace BF51442C,Thermolyne benchtop muffle furnace F48025 60.
Choose a temperature controller that,fits your needs. Utilize our furnace s controllers and programmers for rigorous industrial. scientific and laboratory research and production applications. Various control options are offered for our three main Thermo Scientific Thermolyne furnace. furnace product families controllers with PID microprocessor technology. Thermo Scientific Thermolyne furnaces A1 Digital single setpoint control. Thermo Scientific Lindberg Blue M furnaces Dual display shows actual temperature and setpoint. Thermo Scientific furnaces no mechanical over temperature protection relay. Control sophistication ranges from single set included. point to more versatile microprocessor based 1 Digital single setpoint control with a single. systems with temperature ramping programming and ramp to setpoint and a dwell. communications options The choice for each product Dual display shows actual temperature and setpoint. provides the best solution for your application mechanical over temperature protection relay is. Integral contollers available in three product families. 1 Digital programmable control with one stored, are self contained and mounted in the main control. program of 8 segments, panel of the furnace saving space and allowing easy. Mechanical over temperature protection relay is,access with quick plug in maintenance All of our. Thermolyne and Thermo Scientific product lines come. with integral controls as many of the Lindberg Blue M Dual display shows actual temperature and setpoint. models D1 Digital programmable control with 4 stored. programs 16 segments per program and RS 232, Independent contollers available for select models communications interface.
can be positioned adjacent to or remote from the Mechanical over temperature protection relay. furnace allowing the operator to use the furnace in is included. fume hoods or containment areas The controls can Dual display shows actual temperature and setpoint. also be placed or grouped for easy monitoring and,RS232 communications interface provides two. control Select models of our Lindberg Blue M,way communications between furnace and remote. Adjustable over temperature protection provides computer cable software computer are not. additional peace of mind to the user This safety included. feature overrides the main controller and shuts off the. furnace s power if high limit is reached It is available on Note Thermo Fisher Scientific does not provide any software. many controls standard or as an option software support Suggested suppliers are. Eurotherm itools software visit, We only use reliable high quality controls from the www eurotherm co uk products temperature controller. specialized manufacturers Eurotherm and Yokogawa programmers config software eurotherm itools. Specview itools software visit www specview com, Thermo Scientific Lindberg Blue M furnace Thermo Scientific box furnace controllers provide. controllers with PID microprocessor technology a choice of electronic and microprocessor technology. A Digital single setpoint control A2 Electronic single setpoint control Digicon. Single segment single setpoint one ramp to setpoint C2 Programmable digital control. Digital single program multiple segment,B Thermicon P free programming of up to 9 program.
programmable control steps, Single program with 16 segments for ramp up and Set actual value indicator integrated timer for. down and dwell timed hold temperature control activating and deactivating heating max 99 hrs 59. Simultaneous LED display of actual temperature vs min per program step. setpoint Additional choices available by model, Super Control Fuzzy logic suppresses overshooting Upper limit cut out for peace of mind. of temperature 24 hour timer for automatic heat up shut down. Customer initiated auto tune function will adjust and E xhaust fan. update the PID parameters to the optimum settings,Adjustable air supply for incinerating processes. for new temperature setpoints,Digital multiple program multiple segment. programmable control,Up to 30 programs and up to 300 segments.
RS485 digital communications port available as an,for ramp up and down and dwell timed hold. option on select models with programmable control,temperature control Maximum of 99 segments per. program Provides two way communications between furnace. Program patterns can be based on either time or rate and remote computer note cable software. Large 5 digit LED display of actual temperature computer is not included. LCD display provides trend recording function Allows remote monitoring and control of furnace. graphic prompts configurable display data equipment. RS485 digital communications port available as Ability to connect up to 30 furnaces to one personal. an option on select models add COM to model computer. number before last letter as shown in note under 9 pin connection ports. spec table Ordering instructions, D Over temperature control OTC available as an Add COM to model number before last letter as. option on most models shown in note under spec table. Adjustable digital over temperature control protects Twenty five foot cable and RS 232 converter for. furnace and load in the event of primary control connection of furnace control console RS 485 port. circuit failure available on selected models with B to personal computer serial port Required for first. suffix designation see spec table unit connection Accessory No 7043. Overrides main controller and shuts off power to Cable to connect multiple 2 furnaces ovens or. furnace if high limit is reached other equipment with Yokogawa communications. Manual re set required for safety capabilities to first furnace with Yokogawa RS 485. Operates via magnetic contacts through signal from communication port Accessory No 7044. independent thermocouple, ote that Thermo Fisher Scientific is not providing any software. software support Suggested suppliers, urotherm e g itools software please visit www eurotherm.
co uk products temperature controller programmers config. software eurotherm itools,Specview software please go to www specview com. Thermo Scientific Thermolyne small,Box furnaces,benchtop muffle furnaces. Fast heatup and outstanding energy efficiency,vailable in two capacities that. A Door safety switch stops power, reach a maximum temperature of to heating elements when door is. 1100 C opened, Digital single setpoint temperature Thermocouple break protection.
control to 1100 C cuts power to heating elements, Dual display shows actual preventing failure runaway condition. temperature and setpoint 0 95cm 0 38 in diameter port. Ceramic fiber insulation designed in chamber rear for monitoring. to permit faster heatup reducing temperatures with independent. energy consumption measuring devices, Embedded heating elements on top Temperature controller options Applications. and both sides designed to improve Control A1,Heat treatment of small steel parts. temperature uniformity See page 6 for control details. Conducting gravimetric analysis,Drop down door doubles as a shelf. Determination of volatile and,for loading and unloading.
suspended solids,Temp Stability Shipp ing, Cat No Capacity Temp Range interior D x W x H Exterior L x W x H Electrical Plug Type. Uniformity Weight, 0 3 C at 1000 C 13 x 10 3 x 9 8 cm 33 x 23 x 36 cm 120 V 50 60 Hz 9 kg. FB1315M 1 3L 0 04 cu ft 100 to 1100 C 7 8 C at 1000 C 5 x 4 x 3 8 in 13 x 9 x 14 in 1060 W 8 9 A 20 Lb. 0 3 C at 1000 C 13 x 10 3 x 9 8 cm 33 x 23 x 36 cm 208 V 50 60 Hz 9 kg. FB1318M 1 3L 0 04 cu ft 100 to 1100 C 7 8 C at 1000 C 5 x 4 x 3 8 in 13 x 9 x 14 in 1060 W 5 1 A 20 Lb. 0 3 C at 1000 C 13 x 10 3 x 9 8 cm 33 x 23 x 36 cm 240 V 50 60 Hz 9 kg. FB1310M 1 3L 0 04 cu ft 100 to 1100 C 7 8 C at 1000 C 5 x 4 x 3 8 in 13 x 9 x 14 in 1060 W 4 4 A 20 Lb. 0 3 C at 1000 C 13 x 10 3 x 9 8 cm 33 x 23 x 36 cm 100 V 50 60 Hz 9 kg. FB1314M 1 3L 0 04 cu ft 100 to 1100 C 7 8 C at 1000 C 5 x 4 x 3 8 in 13 x 9 x 14 in 1060 W 10 6 A 20 Lb. 0 3 C at 1000 C 13 x 10 3 x 9 8 cm 33 x 23 x 36 cm 240 V 50 60 Hz 9 kg. FB1310M 33CN 1 3L 0 04 cu ft 100 to 1100 C 7 8 C at 1000 C 5 x 4 x 3 8 in 13 x 9 x 14 in 1060 W 4 4 A 20 Lb. NEMA 5 20 10 A, 0 3 C at 1000 C 13 x 10 3 x 9 8 cm 33 x 23 x 36 cm 240 V 50 60 Hz 9 kg. FB1310M 33CH 1 3L 0 04 cu ft 100 to 1100 C 7 8 C at 1000 C 5 x 4 x 3 8 in 13 x 9 x 14 in 1060 W 4 4 A NEMA 5 20. 0 3 C at 1000 C 13 x 10 3 x 9 8 cm 33 x 23 x 36 cm 240 V 50 60 Hz 9 kg. FB1310M 33UK 1 3L 0 04 cu ft 100 to 1100 C 7 8 C at 1000 C 5 x 4 x 3 8 in 13 x 9 x 14 in 1060 W 4 4 A NEMA 5 20 20 Lb. 0 5 C at 1000 C 15 2 x 12 7 x 10 8 cm 40 x 25 x 37 cm 120 V 50 60 Hz 12 7 kg NEMA 5 20. FB1415M 2 1L 0 07 cu ft 100 to 1100 C 5 0 C at 1000 C 6 x 5 x 4 25 in 15 8 x 10 x 14 5 in 1450 W 12 0 A 28 Lb NEMA 5 20. 0 5 C at 1000 C 15 2 x 12 7 x 10 8 cm 40 x 25 x 37 cm 208 V 50 60 Hz 12 7 kg. FB1418M 2 1L 0 07 cu ft 100 to 1100 C NEMA 5 20, 5 0 C at 1000 C 6 x 5 x 4 25 in 15 8 x 10 x 14 5 in 1520 W 7 3 A 28 Lb. 0 5 C at 1000 C 15 2 x 12 7 x 10 8 cm 40 x 25 x 37 cm 240 V 50 60 Hz 12 7 kg. FB1410M 2 1L 0 07 cu ft 100 to 1100 C 5 0 C at 1000 C 6 x 5 x 4 25 in 15 8 x 10 x 14 5 in 1520 W 6 3 A 28 Lb. 0 5 C at 1000 C 15 2 x 12 7 x 10 8 cm 40 x 25 x 37 cm 240 V 50 60 Hz 12 7 kg. FB1410M 33 2 1L 0 07 cu ft 100 to 1100 C 5 0 C at 1000 C 6 x 5 x 4 25 in 15 8 x 10 x 14 5 in 1520 W 6 3 A 28 Lb. 0 5 C at 1000 C 15 2 x 12 7 x 10 8 cm 40 x 25 x 37 cm 240 V 50 60 Hz 12 7 kg. FB1410M 33CN 2 1L 0 07 cu ft 100 to 1100 C 5 0 C at 1000 C 6 x 5 x 4 25 in 15 8 x 10 x 14 5 in 1520 W 6 3 A 28 Lb NEMA 5 20. FB1410M 33 0 5 C at 1000 C 15 2 x 12 7 x 10 8 cm 40 x 25 x 37 cm 240 V 50 60 Hz 12 7 kg. 2 1L 0 07 cu ft 100 to 1100 C, CH 5 0 C at 1000 C 6 x 5 x 4 25 in 15 8 x 10 x 14 5 in 1520 W 6 3 A NEMA 5 20 28 Lb.
FB1410M 33 0 5 C at 1000 C 15 2 x 12 7 x 10 8 cm 40 x 25 x 37 cm 240 V 50 60 Hz. 2 1L 0 07 cu ft 100 to 1100 C, UK 5 0 C at 1000 C 6 x 5 x 4 25 in 15 8 x 10 x 14 5 in 1520 W 6 3 A NEMA 5 20. 0 5 C at 1000 C 15 2 x 12 7 x 10 8 cm 40 x 25 x 37 cm 100 V 50 60 Hz 12 7 kg NEMA 5 20. FB1414M 2 1L 0 07 cu ft 100 to 1100 C 5 0 C at 1000 C 6 x 5 x 4 25 in 15 8 x 10 x 14 5 in 1450 W 14 5 A 28 Lb. Hearth plates Ordering Information Replacement heating elements and thermocouples available separately. Cat No For Use With Includes Thermocouple line cord and hearth plate to protect bottom of unit NEMA 5 20. PH44X1 FB1300 small muffle furnace Warranty 1 year parts and labor. PH48X1 FB1400 small muffle furnace Certifications 33 units are CE marked all other units are C. Thermolyne and Thermo Scientific product lines come with integral controls as many of the Lindberg Blue M models Independent contollers available for select models can be positioned adjacent to or remote from the furnace allowing the operator to use the furnace in fume hoods or containment areas The controls can

Related Books