Summary of Changes, This publication contains new and updated information as indicated in the following table. Topic Page, Specifications for Stratix 5800 catalog numbers 1783 MMS10BE B 1783 MMS10E B 1783 MMS10ER B 1783 MMS10 B 47 52. 1783 MMS10R B 1783 MMS10B B 1783 MMS10EA B 1783 MMS10EAR B 1783 MMX8EA A 1783 MMX8SA A. Ethernet tap catalog numbers 1783 ETAPK 1783 ETAP1FK 1783 ETAP2FK 75. Additional Resources, These documents contain additional information concerning related products from Rockwell Automation. Resource Description, Configurable NAT Router User Manual publication 1783 UM008 Describes how to install configure and troubleshoot the NAT router. EtherNet IP Industrial Protocol White Paper publication ENET WP001 Describes how to implement services and data objects on a TCP UDP IP based. Ethernet network, Stratix Managed Switches User Manual publication 1783 UM007 Describes how to configure and troubleshoot Stratix 5400 5410 5700 8000 8300.
and ArmorStratix 5700 switches, Stratix 2000 Ethernet Unmanaged Switches User Manual publication 1783 UM011 Describes how to use DIP switches and status indicators on Stratix 2000 switches. Stratix 2500 Lightly Managed Switches User Manual publication 1783 UM009 Describes how to configure and troubleshoot Stratix 2500 switches. Stratix 5800 Ethernet Managed Switches User Manual publication 1783 UM012 Describes how to configure and troubleshoot Stratix 5800 switches. Stratix 6000 Ethernet Managed Switches User Manual publication 1783 UM001 Describes how to configure and troubleshoot Stratix 6000 switches. Stratix 5100 Wireless Access Point Workgroup Bridge User Manual publication 1783 UM006 Describes how to install configure and troubleshoot the wireless access point. Stratix 5900 Services Router User Manual publication 1783 UM005 Describes how to install configure and troubleshoot the router. Stratix 5950 Security Appliance User Manual publication 1783 UM010 Describes how to install configure and troubleshoot the security appliance. Industrial Automation Wiring and Grounding Guidelines publication 1770 4 1 Provides general guidelines for installing a Rockwell Automation industrial system. Product Certifications website http www rockwellautomation com global certification Provides declarations of conformity certificates and other certification details. overview page, You can view or download publications at http www rockwellautomation com literature To order paper copies of. technical documentation contact your local Allen Bradley distributor or Rockwell Automation sales representative. Stratix Ethernet Device Specifications,Stratix 2000 Ethernet Unmanaged Switches Series B. Cat No Total Ports RJ45 Ports 1 SFP Ports 1,1783 US5T B 5 5 FE. 1783 US5TG B 5 5 GE, 1783 US4T1F B 5 4 FE 1 FE multimode preinstalled fiber SFP module.
1783 US4T1H B 5 4 FE 1 FE singlemode preinstalled fiber SFP module. 1783 US8T B 8 8 FE, 1783 US6T2F B 8 6 FE 2 FE multimode preinstalled fiber SFP modules. 1783 US6T2H B 8 6 FE 2 FE singlemode preinstalled fiber SFP modules. 1783 US7T1F B 8 7 FE 1 FE multimode preinstalled fiber SFP module. 1783 US7T1H B 8 7 FE 1 FE singlemode preinstalled fiber SFP module. 1783 US6T2TG2F B 10 6 FE 2 GE 2 FE multimode preinstalled fiber SFP modules. 1783 US6T2TG2H B 10 6 FE 2 GE 2 FE singlemode preinstalled fiber SFP modules. 1783 US8TG2GX B 10 8 GE 2 GE slots 2,1783 US16T B 16 16 FE. 1783 US16T2S B 18 16 FE 2 FE slots 2,1 FE Fast Ethernet GE Gigabit Ethernet. 2 SFP modules must be ordered separately, Table 1 Technical Specifications Stratix 2000 Switches Series B. 1783 US6T2F B,1783 US4T1F B 1783 US6T2H B 1783 US6T2TG2F B.
Attribute 1783 US5T B 1783 US5TG B 1783 US8T B 1783 US8TG2GX B 1783 US16T B 1783 US16T2S B. 1783 US4T1H B 1783 US7T1F B 1783 US6T2TG2H B,1783 US7T1H B. Inrush current 1 85 A 0 33 A 1 69 A 1 31 A 0 41 A 1 83 A 0 55 A 0 47 A 1 63 A. Power input 24V 12 48V DC 18 30V AC 50 60 Hz SELV, consumption 3 4 W 4 5 W 3 4 W 4 6 W 4 6 W 7 5 W 10 W 8 0 W 8 0 W. DC 180 mA DC 250 mA DC 180 mA DC 250 mA DC 250 mA DC 450 mA DC 550 mA DC 430 mA DC 430 mA. Current nom, AC 360 mA AC 500 mA AC 360 mA AC 500 mA AC 500 mA AC 900 mA AC 1100 mA AC 860 mA AC 860 mA. DC 380 mA DC 510 mA DC 380 mA DC 510 mA DC 510 mA DC 850 mA DC 1100 mA DC 900 mA DC 900 mA. Current max, AC 750 mA AC 1020 mA AC 750 mA AC 1100 mA AC 1100 mA AC 1700 mA AC 2200 mA AC 1800 mA AC 1800 mA. ground 2 5 mm2 14 AWG copper wire suitable for 86 C 187 F above surrounding ambient temperature outside the enclosure with a suitable ring terminal. connection, DC power 4 0 25 mm2 12 24 AWG twisted pair copper wire suitable for 86 C 187 F above surrounding ambient temperature outside the enclosure.
connection,Screw torque,ground terminal 0 91 N m 8 05 in lb. Screw torque 0 50 0 56 N m 4 5 5 0 in lb,power terminals. Enclosure type None open style,North American T4 T4A T5 T4 T4 T4 T4 T5. ATEX temp code T4 T4 T4 T4 T4 T4 T4 T4, Rockwell Automation Publication 1783 TD001V EN P December 2019 3. Stratix Ethernet Device Specifications, Table 1 Technical Specifications Stratix 2000 Switches Series B continued.
1783 US6T2F B,1783 US4T1F B 1783 US6T2H B 1783 US6T2TG2F B. Attribute 1783 US5T B 1783 US5TG B 1783 US8T B 1783 US8TG2GX B 1783 US16T B 1783 US16T2S B. 1783 US4T1H B 1783 US7T1F B 1783 US6T2TG2H B,1783 US7T1H B. IECEx temp code T4 T4 T4 T4 T4 T4 T4 T4,MAC addresses 2K 8K 2K 2k 2K 8K 8K 8K. max supported,Ordered separately,1783 SFP100FX,1783 SFP100LX separately. 1783 SFP100EXC 1783 SFP100FX, SFP modules 1 No SFP slots No SFP slots Preinstalled No SFP slots Preinstalled Preinstalled 1783 SFP100ZXC No SFP slots 1783 SFP100LX.
1783 SFP1GSX 1783 SFP100EXC,1783 SFP1GLX 1783 SFP100ZXC. 1783 SFP1GEXE,1783 SFP1GZX, 1 For specifications of preinstalled SFP modules see Table 2 For specifications of SFP modules ordered separately see Table 59. Table 2 Preinstalled SFP Module Specifications Stratix 2000 Switches. Attribute Multimode 100Base FX Singlemode 100Base LX. Central wavelength nm 1310 1310,Transmission distance km 2 20. Applicable distance km 0 2 0 20,Luminous power min db 19 10. Luminous power max db 10 5,Receiving sensitivity dBm 31 34.
Overload luminous power 3 3, Table 3 Environmental Specifications Stratix 2000 Switches Series B. 1783 US5TG B 1783 US4T1F B 1783 US4T1H B 1783 US6T2F B. Attribute 1783 US5T B 1783 US8T B 1783 US6T2H B 1783 US7T1F B 1783 US7T1H B 1783 US6T2TG2F B. 1783 US6T2TG2H B 1783 US8TG2GX B 1783 US16T B 1783 US16T2S B. Temperature operating 10 C Ta 60 C, IEC 60068 2 1 Test Ad Operating Cold 14 F Ta 140 F. 40 C Ta 75 C 40 F Ta 167 F,IEC 60068 2 2 Test Bd Operating Dry Heat. IEC 60068 2 14 Test Nb Operating Thermal Shock,Temperature ambient max 60 C 140 F 75 C 167 F. Temperature surrounding air max 60 C 140 F 75 C 167 F. Temperature nonoperating 40 85 C 40 185 F, IEC 60068 2 1 Test Ab Unpackaged Nonoperating Cold.
IEC 60068 2 2 Test Bb Unpackaged Nonoperating Dry,IEC 60068 2 14 Test Na Unpackaged Nonoperating. Thermal Shock,Relative humidity 5 95 noncondensing. IEC 60068 2 30 Test Db Unpackaged Damp Heat,Vibration 2 g 10 500 Hz. IEC 60068 2 6 Test Fc Operating,Shock operating 15 g. IEC 60068 2 27 Test Ea Unpackaged Shock,Shock nonoperating 30 g.
IEC 60068 2 27 Test Ea Unpackaged Shock, 4 Rockwell Automation Publication 1783 TD001V EN P December 2019. Stratix Ethernet Device Specifications, Table 3 Environmental Specifications Stratix 2000 Switches Series B continued. 1783 US5TG B 1783 US4T1F B 1783 US4T1H B 1783 US6T2F B. Attribute 1783 US5T B 1783 US8T B 1783 US6T2H B 1783 US7T1F B 1783 US7T1H B 1783 US6T2TG2F B. 1783 US6T2TG2H B 1783 US8TG2GX B 1783 US16T B 1783 US16T2S B. Emissions IEC 61000 6 4,CISPR11 IEC 61000 6 4,ESD immunity 6 kV contact discharges. IEC 61000 4 2 8 kV air discharges, Radiated RF immunity 10V m with 1 kHz sine wave 80 AM from 80 2000 MHz. IEC 61000 4 3 20V m with 200 Hz 50 Pulse 100 AM at 1890 MHz. 3V m with 1 kHz sine wave 80 AM from 2000 2700 MHz. EFT B immunity 4 kV at 5 kHz on power ports, IEC 61000 4 4 2 kV at 5 kHz on communication ports.
Surge transient immunity 2 kV line line DM and 4 kV line earth CM on power ports. IEC 61000 4 5 2 kV line earth CM on communication ports. Conducted RF immunity 10V rms with 1 kHz sine wave 80 AM from 150 kHz 80 MHz. IEC 61000 4 6,Environmental rating IP30, Table 4 Certifications Stratix 2000 Switches Series B. 1783 US5TG B 1783 US4T1F B 1783 US4T1H B 1783 US6T2F B. Certifications 1783 US5T B 1783 US8T B, 1783 US6T2H B 1783 US7T1F B 1783 US7T1H B 1783 US6T2TG2H B. when product is marked 1 1783 US6T2TG2F B 1783 US16T B. 1783 US8TG2GX B 1783 US16T2S B, c UL us UL Listed Industrial Control Equipment certified for US and Canada See UL File E65584. UL Listed for Class I Division 2 Group A B C D Hazardous Locations certified for U S and Canada See UL File E194810. CE European Union 2014 30 EU EMC Directive compliant with. EN 61326 1 Meas Control Lab Industrial Requirements. EN 61000 6 2 Industrial Immunity,EN 61000 6 4 Industrial Emissions. EN 61131 2 Programmable Controllers Clause 8 Zone A B. European Union 2011 65 EU RoHS compliant with,EN 50581 Technical documentation.
RCM Australian Radiocommunications Act compliant with. AS NZS CISPR 11 Industrial Emissions, Ex European Union 2014 34 EU ATEX Directive compliant with. EN 60079 0 General Requirements, EN 60079 15 Potentially Explosive Atmospheres Protection n. II 3 G Ex nA IIC T4 Gc,DEMKO 16 ATEX 1816X,IECEx IECEx System compliant with. IEC 60079 0 General Requirements, IEC 60079 15 Potentially Explosive Atmospheres Protection n. II 3 G Ex nA IIC T4 Gc,IECEx UL 16 0169X, KC Korean Certification of Broadcasting and Communications Equipment compliant with.
Framework Act on Telecommunications and Radio Waves Act. EAC Russian Customs Union TR CU 020 2011 EMC Technical Regulation. EtherNet IP ODVA conformance tested to EtherNet IP specifications. BSMI CNS 13438 95 CNS14336 1 99 Taiwan, 1 See the Product Certification link at http www ab com for Declarations of Conformity Certificates and other certification details. Rockwell Automation Publication 1783 TD001V EN P December 2019 5. Stratix Ethernet Device Specifications,Dimensions Stratix 2000 Switches Series B. Figure 1 1783 US5T B 1783 US5TG B 1783 US4T1F B 1783 US4T1H B. 29 6 mm 29 6 mm,1 17 in 1 17 in,33 5 mm 25 0 mm,1 31 in 0 98 in. 3 48 3 mm 35 mm,114 5 mm 1 9 in 1 38 in 20 0 mm,2 4 51 in 0 79 in. 1 43 25 mm, 6 Rockwell Automation Publication 1783 TD001V EN P December 2019.
Stratix Ethernet Device Specifications, Figure 2 1783 US8T B 1783 US6T2F B 1783 US6T2H B 1783 US7T1F B 1783 US7T1H B. 45 6 mm 68 mm 45 6 mm,1 80 in 2 68 in 1 8 in,1 32 in 6 mm. 0 24 in 35 mm,114 5mm 1 9 in 35 mm 20 mm,4 50 in 1 38 in 0 79 in. Rockwell Automation Publication 1783 TD001V EN P December 2019 7. Stratix Ethernet Device Specifications, Figure 3 1783 US6T2TG2F B 1783 US6T2TG2H B 1783 US8TG2GX B. 106 mm 53 6 mm,4 17 in 2 11 in,6 mm 52 0 mm,0 24 in 2 05 in.
5 28 in 48 3 mm,1 90 in 20 0 mm,G1 G2 0 79 in,1 2 2 11 in. 8 Rockwell Automation Publication 1783 TD001V EN P December 2019. Stratix Ethernet Device Specifications,Figure 4 1783 US16T B 1783 US16T2S B. 79 6 mm 106 mm 79 6 mm,3 13 in 4 17 in 3 13 in,9 10 17 18. 1 67 in 6 mm 70 mm,0 24 in 2 76 in,5 6 13 14 134 mm. 5 27 in 48 3 mm 35 mm 20 mm,1 90 in 1 38 in 0 79 in.
1 2 53 5 mm, Rockwell Automation Publication 1783 TD001V EN P December 2019 9. Stratix Ethernet Device Specifications,Stratix 2000 Ethernet Unmanaged Switches Series A. Cat No Total Ports RJ45 Ports 1 Combo Ports 1 SFP Ports 1. 1783 US4T1F A 5 4 FE 1 FE multimode preinstalled fiber SFP module. 1783 US4T1H A 5 4 FE 1 FE singlemode preinstalled fiber SFP module. 1783 US5T A 5 5 FE,1783 US5TG A 5 5 GE, 1783 US6T2F A 8 6 FE 2 FE multimode preinstalled fiber SFP modules. 1783 US6T2H A 8 6 FE 2 FE singlemode preinstalled fiber SFP modules. 1783 US6TG2CG A 8 6 GE 2 GE, 1783 US7T1F A 8 7 FE 1 FE multimode preinstalled fiber SFP module. 1783 US7T1H A 8 7 FE 1 FE singlemode preinstalled fiber SFP module. 1783 US8T A 8 8 FE,1783 US14T2S A 16 14 FE 2 FE 2,1783 US16T A 16 16 FE.
1 FE Fast Ethernet GE Gigabit Ethernet,2 SFP modules must be ordered separately. The following table lists Stratix 2000 series A switches and their series B replacements For specifications of series B. switches see page 3,Table 5 Stratix 2000 Series Change. Series A Cat No Series B Replacement Cat No Change 1. 1783 US4T1F A 1783 US4T1F B Same catalog number and configuration. 1783 US4T1H A 1783 US4T1H B Same catalog number and configuration. 1783 US5T A 1783 US5T B Same catalog number and configuration. 1783 US5TG A 1783 US5TG B Same catalog number and configuration. 1783 US6T2F A 1783 US6T2F B Same catalog number and configuration. 1783 US6T2H A 1783 US6T2H B Same catalog number and configuration. 1783 US7T1F A 1783 US7T1F B Same catalog number and configuration. 1783 US7T1H A 1783 US7T1H B Same catalog number and configuration. 1783 US8T A 1783 US8T B Same catalog number and configuration. 1783 US16T A 1783 US16T B Same catalog number and configuration. 1783 US14T2S A 1783 US16T2S B New catalog number, Replaced 2 GE combo ports with 2 GE copper ports on series B replacement. Stratix Ethernet Device Specifications IECEx temp code T4 T4 T4 T4 T4 T4 T4 T4 MAC addresses max supported 2 K 8 K 2 K 2 k 2 K 8 K 8 K 8 K SFP modules 1 No SFP slots No SFP slots Preinstalled No SFP slots Preinstalled Preinstalled Ordered separately 1783 SFP100FX 1783 SFP100LX 1783 SFP100EXC 1783 SFP100ZXC 1783 SFP1GSX 1783 SFP1GLX 1783

Related Books