ii IMPORTANT INFORMATION FOR USERS OF THIS MANUAL July 21 2015. Introduction, This document is issued by UL LLC and is intended only to be used in conjunction with the Follow Up. Service Procedure and the UL Standard for Electric Signs UL 48 by Manufacturers covered under UL s. Follow Up Services and by UL Representatives conducting UL Follow Up Service Inspections. This Manual contains the names of companies authorized to use the Recognized Marking on or in. connection with components which have been evaluated by UL and found to be in compliance with UL s. requirements These companies as well as the manufacturers and submitters of the products have. entered into an Agreement with UL to use the Recognized Marking only on or in connection with products. manufactured in compliance with UL s requirements It should be noted that Recognized products of. different makes or model designations are not necessarily equivalent in quality or performance. Where products are identified as being Recognized or Classified the appearance of catalog or model. numbers or other specific product designations in this Manual signifies among other things that 1. representative samples of these products have been submitted to UL and found to comply with the. applicable requirements and that 2 the manufacturer has been authorized to use the Recognized. Marking on production that continues to comply with UL s requirements and is subject to UL s Follow Up. Service Manufacturers are not obligated to use the Recognized Marking on all of their production and. products which do not bear the Recognized Marking are not required by UL to comply with UL s. requirements Accordingly the appearance of a company s name or a specific product designation in this. Manual does not in itself assure that the products so specified or identified are subject to UL s Follow Up. Service The manufacturer s products are not subject to UL s Follow Up Service unless they bear the. Recognized Marking Only those products bearing the Recognized and Classification Marking should be. considered as covered by UL s Recognition Classification and Follow Up Service. This Manual contains Component Recognitions in effect as of July 21 2015 Records of Component. Recognitions and Classifications issued or withdrawn after this date will be found in UL s Listing. Information database or historical records In addition Component Recognition s and Classifications. issued after this date will appear in future revisions of this Manual. Use of the Sign Components Manual, UL s Follow Up Service Procedure authorizes manufacturers covered under UL s Listing and Follow Up. Services for Electric Signs UXYT 7 and Field Assembled Skeletal Neon Sign and Outline Lighting. Systems UZBL 7 to apply the specified UL Listing Mark to products which comply with the requirements. expressed in the Follow Up Service Procedure the associated Follow Up and Inspection Instructions. FUII Pages and the UL Standard for Electric Signs UL 48 Compliance with these documents requires. that manufacturers primarily use component products that are UL Listed This Manual authorizes. manufacturers to use certain UL Recognized Components Classified Components and other non Listed. products when they are used under 1 the conditions expressed for the components in this Manual 2. the installation instructions for the component and 3 the requirements expressed in the documents. noted above, This Manual is intended to assist manufacturers who may wish to use a Recognized Component or other. non Listed products in their UL Listed Electric Signs Field Assembled Skeletal Neon Sign and Outline. Lighting Systems For all components consult the Product Category Guide General Information. preceding the individual component listings as well as the individual listings themselves for use conditions. and ratings as well as the required Recognized Marking. This Manual provides the following, authorization to use all components listed when the component is used according to the. requirements of the Follow Up Service Procedure the UL Standard for Electric Signs UL 48 the. associated Follow Up and Inspection Instructions FUII Pages and the specified limitations or. conditions of use, July 21 2015 IMPORTANT INFORMATION FOR USERS OF THIS MANUAL iii.
names of companies which are authorized to provide components bearing a Recognized Marking. as of the date noted in the Introduction on page ii. information about the form and nature of the Recognized Marking to be used by a specific. manufacturer or for a specific class or category of product. information relating to limitations or conditions of use applying to the component. Component Recognitions are arranged alphabetically in this Manual by product category and when. included individual Recognitions are arranged alphabetically by company name under each category. Products which are neither Listed nor Recognized by UL are grouped under the category titled. Miscellaneous and identified by the initials MISC and are arranged alphabetically by their common. When individual Recognitions are not listed following the category title refer to the UL s Recognized. Component Directory for names of companies authorized to use the Recognized Marking and for. components that are authorized to bear the Recognized Marking The products are to be marked by. Company name or UL File Number and catalog designation and when Recognized for use in Canada. Recognized Component Mark for Canada, When included Product Category Guide General Information at the beginning of each product category. except MISC provides important information regarding the scope and limitation of the Component. Recognitions and a general description of the Recognized Marking authorized for Component. Recognition in that category Unless otherwise noted the limitations and conditions of use provided in. the Product Category Guide General Information are to be applied to all components having. Recognition in that category, Some companies may be authorized to use a trade name or trademark for identification of Recognized. Components in place of their company name in such cases refer to UL s Recognized Component. Directory for a reproduction of the trade name or trademark. Products listed under the category identified by the initials MISC may be produced by any manufacturer. Such products are neither UL Listed nor Recognized by UL and UL in no way has established. Agreements with the manufacturers of such products that may be used as a basis to insure their. uniformity or performance, All components must be used for only the purpose intended by their manufacturer and as may be. identified in this Manual and under the conditions of use identified in this Manual However even when. the conditions of use and all other applicable requirements are met UL reserves the right to evaluate. specific constructions incorporating these products and determine suitability. 1 SIGN COMPONENTS MANUAL SAM July 21 2015,FLEXIBLE METAL CONDUIT. Shall be used within a metal sign body and polymeric sign face. Not to be relied upon for grounding or bonding,GASKETS AND SEALS JMLU2.
GASKET MATERIALS JMST2, 1 Suitable for use in an outdoor sign as a weather seal such as for a door or removable cover of a sign body or enclosure. 2 Adhesive alone is not suitable to secure a gasket unless the adhesive has been separately authorized for that application. 3 A gasket material designated to be used in a UL 1598 UL 508 UL 50 application is considered to be suitable for use in an. outdoor sign,MISCELLANEOUS NON RECOGNIZED DEVICES,Christmas Tree Fasteners. 1 Only suitable for use in indoor signs, 2 Only suitable to secure lightweight decorative parts or neon tube supports. 1 Only suitable for use in indoor signs, 2 Not suitable for completing an electrical enclosure. 3 Adhesive alone is not suitable to secure Velcro to non flat surfaces when Velcro is used to secure parts weighing more than 4. INSULATING BUSHINGS NZMT2, 1 Suitable for use as mechanical protection of insulation on low voltage wiring.
2 Suitable for use as low voltage wiring strain relief The strain relief test shall be conducted as described in UL48 Section 34 for. each new unit design The manufacturer shall keep a record of each test The Field Representative shall witness the test. NEON TRANSFORMERS,NEON POWER SUPPLIES PWIK2 PWIK8, This category covers neon transformers and power supplies for use with end products employing gas filled glass tubing identified. as neon or electric discharge tubing,CONDITIONS OF ACCEPTABILITY. Each Recognized Component has Conditions of Acceptability that define the parameters of use for the component in an end use. product Conditions of Acceptability are identified in the individual Recognitions by one or more letters appearing next to the model. designation or catalog number under the heading Conditions of Acceptability The letters that appear identify which of the. Conditions of Acceptability apply to the particular model or catalog number Where the Conditions of Acceptability require testing. or are unique to the component the letters TR appear next to the model designation or catalog number under the heading. Conditions of Acceptability and reference will need to be made to the individual Recognition Report. A Intended for use only in applications that comply with the requirements of the end product. B Suitable for use only indoors, C Suitable for use outdoors where protected from rain snow and water spray. D Suitable for use only where the neon tubing between the neon supply electrode receptacles is either a one continuous. length of tubing or b multiple lengths of tubing interconnected only with Listed more than 1000 V lampholders see OJOV of. the lamp to lamp type Listed or Recognized Component Sign Accessories UYMR 2 and Listed Gas Tube Sign and Ignition. Cable GTO Cable ZJQX are not acceptable for interconnecting neon tubing lengths in any part of the secondary circuit. E Suitable for use only where contained in an end use product compartment that is suitable as an electrical enclosure. F Suitable for use only where made inaccessible to contact by users during user maintenance while energized. G Provided with connection means suitable for factory wiring only not for field wiring. H Not provided with a means of connection in accordance with NFPA 70 National Electrical Code therefore suitable. means needs to be provided in the end use product, TR Requires testing or other evaluation in the end product refer to individual Recognition Report. PRODUCT MARKINGS, Transformers and power supplies covered under this category are marked Indoors Outdoors Weatherproof or WP.
Products marked Indoors are only suitable for use indoors and products marked Outdoors are suitable for use indoors or. outdoors sheltered from rain snow and the like by being located within a sign body enclosure and the like Products marked. Weatherproof or WP do not need to be additionally sheltered from rain snow and the like. July 21 2015 SIGN COMPONENTS MANUAL SAM 2, Transformers and power supplies covered under this category are marked with a Type number from 1 to 8 in association with the. location designation Indoors Outdoors Weatherproof or WP These Type numbers identify particular construction features. associated with a particular transformer or power supply as identified below. Type 1 Open core and coil neon transformer or unenclosed neon power supply with body of the unit and input and output. terminals or leads that should be enclosed in accordance with end product requirements. Type 2 Neon supply with input and output terminals or leads that should be enclosed in accordance with end product. requirements, Type 3 Neon supply with input terminals or leads enclosed and intended for connection to a permanent wiring system and. with output terminals or leads that should be enclosed in accordance with end product requirements. Type 4 Neon supply with input and output terminals or leads enclosed and intended for connection to a permanent wiring. Type 5 Neon supply with input terminals or leads enclosed and intended for connection to a permanent wiring system and. provided with integral receptacles for output connection. Type 6 Cord connected neon supply provided with integral receptacles for output connection. Type 7 Cord connected neon supply with output terminals or leads that should be enclosed in accordance with end product. requirements, Type 8 Cord connected neon supply with enclosed output terminals or leads. ALLANSON INTERNATIONAL INC E39591,33 CRANFIELD RD,TORONTO ONTARIO CANADA M4B 3H2. Neon Power Supply Indoor Type 7 Cat No SS935B 18,Transformers Outdoor Type 5.
Applicable Conditions of Use C D E, Cat Nos 960EK120 960EK277 960EK347 P960EK120 P960EK277 P960EK347 960EKF120 960EKF277 960EKF347. P960EKF120 P960EKF277 P960EKF347 7560EK277 7560EK347 P7560EK120 P7560EK277 P7560EK347 7560EKF277. P7560EKF120 P7560EKF277 P7560EKF347 660EK120 660EK277 660EK347 P660EK120 P660EK277 P660EK347. 660EKF120 660EKF277 660EKF347 P660EKF120 P660EKF277 P660EKF347 560EK120 560EK347 P560EK120. P560EK277 P560EK347 560EKF120 560EKF347 P560EKF120 P560EKF277 P560EKF347 460EK120 460EK277. 460EK347 P460EK120 P460EK277 P460EK347 460EKF120 460EKF277 460EKF347 P460EKF120 P460EKF277. P460EKF347 360EK120 360EK277 360EK347 P360EK120 P360EK277 P360EK347 360EKF120 360EKF277 360EKF347. P360EKF120 P360EKF277 P360EKF347,Transformers Outdoor Type 5. This Manual is intended to assist manufacturers who may wish to use a Recognized Component or other non Listed products in their UL Listed Electric Signs Field Assembled Skeletal Neon Sign and Outline Lighting Systems For all components consult the Product Category Guide General Information preceding the individual component listings as well as the individual listings themselves for use