ISBN 978 0 626 25188 8,SANS 10400 T 2011,SOUTH AFRICAN NATIONAL STANDARD. The application of the National Building,Regulations. Part T Fire protection,Published by SABS Standards Division. 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001. Tel 27 12 428 7911 Fax 27 12 344 1568,www sabs co za. SANS 10400 T 2011,Table of changes,Change No Date Scope.
This South African standard was approved by National Committee SABS SC 21E Fire safety Fire. threat to the community and environment in accordance with procedures of the SABS Standards. Division in compliance with annex 3 of the WTO TBT agreement. This document was published in March 2011, This document supersedes the corresponding parts of SABS 0400 1990 first revision. Compliance with the requirements of this document will be deemed to be compliance with the. requirements of part T of the National Building Regulations issued in terms of the National Building. Regulations and Building Standards Act 1977 Act No 103 of 1977. SANS 10400 consists of the following parts under the general title The application of the National. Building Regulations,Part A General principles and requirements. Part B Structural design,Part C Dimensions,Part D Public safety. Part F Site operations,Part G Excavations,Part H Foundations. Part J Floors,Part K Walls,Part L Roofs,Part M Stairways.
Part N Glazing,Part O Lighting and ventilation,Part P Drainage. Part Q Non water borne means of sanitary disposal,Part R Stormwater disposal. SANS 10400 T 2011,Foreword concluded,Part S Facilities for persons with disabilities. Part T Fire protection,Part V Space heating,Part W Fire installation. This document should be read in conjunction with SANS 10400 A. Annexes A and B form an integral part of this document Annexes C and D are for information only. SANS 10400 T 2011,This page is intentionally left blank.
SANS 10400 T 2011,2 Normative references 5,3 Definitions 8. 4 Requirements 17,4 1 General 17,4 2 Safety distances 18. 4 3 Different occupancies in a building 23,4 4 Division area 23. 4 5 Fire performance 23, 4 6 Fire resistance of occupancy separating and division separating elements 24. 4 7 Fire stability of structural elements or components 25. 4 8 Tenancy separating elements 25,4 9 Partition walls and partitions 26.
4 10 Protection of openings 29, 4 11 Raised access and suspended floors of combustible material 30. 4 12 Roof assemblies and coverings 31,4 13 Ceilings 33. 4 14 Floor coverings 34,4 15 Internal finishes 36,4 16 Provision of escape routes 37. 4 17 Exit doors 39,4 18 Feeder routes 39,4 19 Emergency routes 39. 4 20 Dimensions of components of escape routes 40,4 21 Width of escape routes 41.
4 22 Basements 42, 4 23 Stairways and other changes of level along escape routes 42. 4 24 Ventilation of stairways in an emergency route 43. 4 25 Pressurization of emergency routes and components 43. 4 26 Openings in floors 43,4 27 External stairways and passages 43. 4 28 Lobbies foyers and vestibules 44,4 29 Marking and signposting 44. 4 30 Provision of emergency lighting 45,4 31 Fire detection and alarm systems 45. 4 32 Provision and maintenance of fire fighting equipment installations and. fire protection systems 46, 4 33 Water reticulation for fire fighting purposes 46.
4 34 Hose reels 46,4 35 Hydrants 47, 4 36 Automatic sprinkler and other fixed extinguishing systems 47. SANS 10400 T 2011,Contents concluded,4 37 Portable fire extinguishers 47. 4 38 Mobile fire extinguishers 48, 4 39 Fire stopping of inaccessible concealed spaces 50. 4 40 Protection in service shafts 50, 4 41 Services in structural or separating elements 51. 4 42 Smoke control 51, 4 43 Air conditioning and artificial ventilation systems 52.
4 44 Lift shafts 53,4 45 Lifts 53,4 46 Firemen s lift 53. 4 47 Stretcher lift 54,4 48 Stage and backstage areas 54. 4 49 Seating arrangements in auditoriums or halls and on grandstands 56. 4 50 Parking garages 58, 4 51 Operating theatres and intensive high or critical care units 58. 4 52 Installation of liquid fuel dispensing pumps and tanks 58. 4 53 Installation of other tanks 59, 4 54 Access for fire fighting and rescue purposes 60. 4 55 Presumed fire resistance of building materials and components 60. 4 56 Building materials 66, 4 57 Single storey category 1 buildings for H3 and H4 occupancies 67.
4 58 Guest houses and bed and breakfast accommodation 68. 4 59 Health care facilities 69, Annex A normative National Building Regulations Part T Fire Protection 70. Annex B normative Rational designs 71, Annex C informative Appointment of competent persons 76. Annex D informative Application of some of the requirements of. this part of SANS 10400 78,Bibliography 86,SANS 10400 T 2011. The application of the National Building Regulations. Fire protection, This part of SANS 10400 provides deemed to satisfy requirements for compliance with part T Fire. Protection of the National Building Regulations, NOTE Part T of the National Building Regulations issued in terms of the National Building Regulations and.
Building Standards Act 1977 Act No 103 of 1977 is reproduced in Annex A. 2 Normative references, The following referenced documents are indispensable for the application of this document For. dated references only the edition cited applies For undated references the latest edition of the. referenced document including any amendments applies Information on currently valid national. and international standards can be obtained from the SABS Standards Division. BS 7974 Application of fire safety engineering principles to the design of buildings Code of. EN 1125 Building hardware Panic exit devices operated by a horizontal bar for use on escape. routes Requirements and test methods,EN 12101 all parts Smoke and heat control systems. EN 14064 all parts Thermal insulation products for buildings In situ formed loose fill mineral. wool MW products, PD 7974 all parts Application of fire safety engineering principles to the design of buildings. SANS 193 Fire dampers, SANS 306 4 Fire extinguishing installations and equipment on premises Part 4 Specification for. carbon dioxide systems, SANS 428 Fire performance classification of thermal insulated building envelope systems.
SANS 543 Fire hose reels with semi rigid hose, SANS 1128 1 Firefighting equipment Part 1 Components of underground and above ground. hydrant systems,SANS 10400 T 2011, SANS 1128 2 Firefighting equipment Part 2 Hose couplings connectors and branch pipe and. nozzle connections, SANS 1151 Portable rechargeable fire extinguishers Halogenated hydrocarbon type. extinguishers, SANS 1186 1 Symbolic safety signs Part 1 Standard signs and general requirements. SANS 1186 3 Symbolic safety signs Part 3 Internally illuminated signs. SANS 1186 5 Symbolic safety signs Part 5 Photoluminescent signs. SANS 1253 Fire doors and fire shutters, SANS 1464 22 Safety of luminaires Part 22 Luminaires for emergency lighting.
SANS 1475 1 The production of reconditioned fire fighting equipment Part 1 Portable and. wheeled mobile rechargeable fire extinguishers, SANS 1475 2 The production of reconditioned fire fighting equipment Part 2 Fire hose reels and. above ground hydrants,SANS 1910 Portable refillable fire extinguishers. SANS 2001 EM1 Construction works Part EM1 Cement plaster. SANS 10082 Timber frame buildings, SANS 10087 2 SABS 087 2 The handling storage and distribution of liquefied petroleum gas in. domestic commercial and industrial installations Part 2 Installations in mobile units and small. non permanent buildings, SANS 10087 3 The handling storage distribution and maintenance of liquefied petroleum gas in. domestic commercial and industrial installations Part 3 Liquefied petroleum gas installations. involving storage vessels of individual water capacity exceeding 500 L. SANS 10087 7 The handling storage distribution and maintenance of liquefied petroleum gas in. domestic commercial and industrial installations Part 7 Storage and filling premises for refillable. liquefied petroleum gas LPG containers of gas capacity not exceeding 9 kg and the storage of. individual gas containers not exceeding 48 kg, SANS 10087 10 The handling storage distribution and maintenance of liquefied petroleum gas in.
domestic commercial and industrial installations Part 10 Mobile filling stations for refillable. liquefied petroleum gas LPG containers of capacity not exceeding 9 kg. SANS 10089 3 The petroleum industry Part 3 The installation modification and. decommissioning of underground storage tanks pumps dispensers and pipework at service. stations and consumer installations, SANS 10100 1 SABS 0100 1 The structural use of concrete Part 1 Design. SANS 10105 1 The use and control of fire fighting equipment Part 1 Portable and wheeled. mobile fire extinguishers, SANS 10114 2 Interior lighting Part 2 Emergency lighting. SANS 10131 Above ground storage tanks for petroleum products. SANS 10400 T 2011, SANS 10139 Fire detection and alarm systems for buildings System design installation and. SANS 10145 SABS 0145 Concrete masonry construction. SANS 10177 2 Fire testing of materials components and elements used in buildings Part 2 Fire. resistance test for building elements, SANS 10177 3 Fire testing of materials components and elements used in buildings Part 3. Surface fire index of finishing materials, SANS 10177 4 Fire testing of materials components and elements used in buildings Part 4.
Surface fire index of floor coverings, SANS 10177 5 Fire testing of materials components and elements used in buildings Part 5 Non. combustibility at 750 C of building materials, SANS 10177 10 Fire testing of materials components and elements used in buildings Part 10. Surface burning characteristics of building materials using the inverted channel tunnel test. SANS 10177 11 Fire testing of materials components and elements used in buildings Part 11. Large scale fire performance evaluation of building envelope thermal insulation systems with or. without sprinklers, SANS 10263 0 The warehousing of dangerous goods Part 0 General requirements. SANS 10287 SABS 0287 Automatic sprinkler installations for fire fighting purposes. SANS 10313 Protection against lightning Physical damage to structures and life hazard. SANS 10400 A 2010 The application of the National Building Regulations Part A General. principles and requirements, SANS 10400 D The application of the National Building Regulations Part D Public safety. SANS 10400 M SABS 0400 M The application of the National Building Regulations Part M. SANS 10400 N The application of the National Building Regulations Part N Glazing. SANS 10400 O The application of the National Building Regulations Part O Lighting and. ventilation, SANS 10400 S SABS 0400 S The application of the National Building Regulations Part S.
Facilities for persons with disabilities, SANS 10400 W The application of the National Building Regulations Part W Fire installation. SANS 11601 Wheeled fire extinguishers Performance and construction. SANS 14520 1 ISO 14520 1 Gaseous fire extinguishing systems Physical properties and system. design Part 1 General requirements, SANS 50054 7 EN 54 7 Fire detection and fire alarm systems Part 7 Smoke detectors Point. detectors using scattered light transmitted light or ionization. SANS 50197 1 EN 197 1 Cement Part 1 Composition specifications and conformity criteria for. common cements,SANS 10400 T 2011, SANS 62305 3 IEC 62305 3 Protection against lightning Part 3 Physical damage to structures. and life hazard,3 Definitions, For the purposes of this document the definitions given in SANS 10400 A some of which are. repeated for convenience and the following apply,acceptable.
acceptable,a in the opinion of any local authority or. b in relation to any document issued by the council in the opinion of the council. access door,entrance door to an emergency route,accredited certification body. certification body that has been accredited by a government endorsed accreditation body. a in the opinion of any local authority or, b in relation to any document issued by the council in the opinion of the council. Agr ment certificate, certificate that confirms fitness for purpose of a non standardized product material or component or. the acceptability of the related non standardized design and the conditions pertaining thereto or. both issued by the Board of Agr ment South Africa,air conditioning system.
system of mechanical ventilation where air that has been filtered is supplied to a building under. conditions of controlled temperature humidity distribution and movement. pipe tube conduit or enclosed space used or to be used in any building for the transmission of air. in an artificial ventilation system or air conditioning system. a by any local authority or, b by the Review Board on appeal to the Review Board in terms of the Act. artificial ventilation system, system in which air is caused to circulate through a room by means of a mechanical apparatus. which forces air into or extracts air from such room. SANS 10400 T 2011, fitted with a suitable device which is activated by a predetermined amount of heat smoke. combustion gases or flame without the need for any manual operat. SANS 10400 T 2011 Edition 3 Table of changes Change No Date Scope Foreword This South African standard was approved by National Committee SABS SC 21E Fire safety Fire threat to the community and environment in accordance with procedures of the SABS Standards Division in compliance with annex 3 of the WTO TBT agreement