Interchangeable trip module makes changing tripping. characteristics a snap even after wiring,Adjustable thermal and magnetic trip settings. Overcurrent short circuit protection and motor switching See Next Page for. functions are combined in one compact unit all functions are UL CSA Application. ambient compensated and phase failure sensitive Ratings Guide. Worldwide approvals including UL 508 CSA 22 2 No 14. One frame size simplifies engineering and reduces stocking cost. Manual motor controller with adjustable magnetic and thermal standard trip module. Adjustable Adjustable Typical Maximum Horsepower,UL CSA Short thermal trip setting. circuit current range set current of, rating kA RMS to motor magnetic Typical Single Phase Typical Three Phase Auxiliary. sym FLC trips HP HP Contacts Catalog, 480 V AC 600 V AC A A 115V 200V 240V 200V 240V 480V 600V NO NC Number Price. See note below,PKZ2 ZM 0 6,65 42 1 1 6 14 22 1 10 1 3 1 0 0 PKZ2 ZM 1 6 488.
Manual Motor, 65 42 1 6 2 4 20 35 1 8 1 6 1 1 0 0 PKZ2 ZM 2 4 488. Controllers, 65 42 2 4 4 35 55 1 8 1 3 1 1 2 3 0 0 PKZ2 ZM 4 488. 65 42 4 6 50 80 1 1 3 5 0 0 PKZ2 ZM 6 488,65 42 6 10 80 140 1 1 2 3 5 7 0 0 PKZ2 ZM 10 488. 65 42 10 16 130 220 1 2 2 3 5 10 10 0 0 PKZ2 ZM 16 488. 65 42 16 25 200 350 2 3 3 5 7 20 25 0 0 PKZ2 ZM 25 552. 65 42 24 32 275 425 2 5 5 10 10 20 0 0 PKZ2 ZM 32 680. 65 42 32 42 350 500 3 5 7 10 15 30 0 0 PKZ2 ZM 40 780. Horsepower ratings shown in the table are for reference only. The final selection of the manual starter depends on the actual motor full load. current and service factor on the motor nameplate, Overload should be set at motor FLA full load current and is calibrated to 1 15 S F. Specified values to NEC table 430 150,Ordering Instructions.
1 Determine the motor FLA and Service Factor,2 Use the application rating guide on next page. 3 Locate the desired manual motor controller All types have adjustable dial for setting motor full load current Trip current is. 4 See pages C51 C56 for auxiliaries and accessories 125 of set value For motors with a service factor SF of 1 0 set dial to 90 of. motor full load current, C48 moellerNA com Discount Code A31 STARTER CAT NA 0708. Manual Motor Controller, with Adjustable Thermal and Magnetic Standard Trip Module. UL CSA Application Ratings Guide for PKZ2 ZM,Maximum short circuit current kA when used as. Manual Controller in Group,Manual Motor Starter Installation Max Circuit.
Catalog Max Fuse Breaker,Number 240V 480V 600V 480V 600V A A. PKZ2 ZM 0 6,PKZ2 ZM 1 6 100 65 42 65 42 500 600,Manual Motor. PKZ2 ZM 2 4 100 65 42 65 42 500 600,Controllers,PKZ2 ZM 4 100 65 42 65 42 500 600. PKZ2 ZM 6 100 65 42 65 42 500 600,PKZ2 ZM 10 100 65 42 65 42 500 600. PKZ2 ZM 16 100 65 42 65 42 500 600,PKZ2 ZM 25 100 65 42 65 42 500 600.
PKZ2 ZM 32 100 65 42 65 42 500 600,PKZ2 ZM 40 100 65 42 65 42 500 600. STARTER CAT NA 0708 moellerNA com C49,Basic Components. Base Modules Trip Modules,Basic Components,Adjustable Adjustable. thermal trip setting Typical Maximum Horsepower,range set current of. to motor magnetic Typical Three Phase,FLC trips HP Contacts For use Catalog.
Module Description A A 200V 240V 480V 600V NO NC with Number Price. Base Module,Maximum con all other,As per the trip module inserted. tinuous motor load 0 0 PKZ2 PKZ2 320,current 42A see below for selection. Standard Trip Module,0 4 0 6 5 8 0 0 ZM 0 6 PKZ2 160. 0 6 1 8 14 see note below 0 0 ZM 1 PKZ2 160,1 1 6 14 22 1 0 0 ZM 1 6 PKZ2 168. C Standard trip,module for PKZ2,1 6 2 4 20 35 1 1 0 0 ZM 2 4 PKZ2 168.
Adjustable thermal 2 4 4 35 55 1 1 2 3 0 0 ZM 4 PKZ2 168. and magnetic trips PKZ2,4 6 50 80 1 1 3 5 0 0 ZM 6 PKZ2 168. Manual Motor,Includes a manual PKZ2 S SP,Controllers. test feature and 6 10 80 140 2 3 5 7 0 0 ZM 10 PKZ2 168. tamper preventive, settings cover 10 16 130 220 3 5 10 10 0 0 ZM 16 PKZ2 168. 16 25 200 350 7 7 20 25 0 0 ZM 25 PKZ2 232,24 32 275 425 10 10 20 30 0 0 ZM 32 PKZ2 360. 32 42 350 500 10 15 30 30 0 0 ZM 40 PKZ2 460, Horsepower ratings shown in the table are for reference only.
The final selection of the manual starter depends on the actual motor full load. current and service factor on the motor nameplate, Overload should be set at motor FLA full load current and is calibrated to 1 15 S F. Specified values to NEC table 430 150,Ordering Instructions. 1 Determine the motor FLA and Service Factor,2 Locate the desired trip module. 3 Order trip module and base module separately All types have adjustable dial for setting motor full load current Trip current is. 4 See pages C51 C56 for auxiliaries and accessories 125 of set value For motors with a service factor SF of 1 0 set dial to 90 of. motor full load current, C50 moellerNA com Discount Code A31 STARTER CAT NA 0708. Accessories,Current Limiter Coding Pins,Current Limiter.
Module Description Schematic For use with Catalog Number Price. Current Limiter,Max rated operational voltage Ue 690 V. Rated uninterrupted current Iu 40 A,Can be fitted to controller with mounting PKZ2. CL PKZ2 436, plate C PKZ2 or can be fitted individually with I PKZ2 ZM. mounting base EZ PKZ2 T,See page C65 for capacity ratings. Tamper preventive coding pins, Accessory Description For use with Catalog Number Price.
Coding Pins, Tamper preventive feature used to pair proper trip module with. base module,Once inserted coding pins are not removable. PKZ2 ZM CS PKZ2 6 90, Deters tampering or an accidental incorrect insertion during. maintenance,Unique coding for up to 6 different trip modules. Easy to use Coding Pins Example of unique coding for up to 6 different trip modules. Manual Motor, Just snap pins off into intended slots see diagram on right.
Controllers,If you have Then code all trip,Code the base A B. this controller modules of this type,module C D,examples with same coding. Examples of Break off Break off,main switch and Base pins in Trip module pins in. trip module pairs module slots on from example slots on. PKZ2 ZM 0 6 PKZ2 C D ZM 0 6 PKZ2 1 2,PKZ2 ZM 1 PKZ2 B D ZM 1 PKZ2 1 3. PKZ2 ZM 1 6 PKZ2 B C ZM 1 6 PKZ2 1 4,PKZ2 ZM 2 4 PKZ2 A D ZM 2 4 PKZ2 2 3.
PKZ2 ZM 4 PKZ2 A C ZM 4 PKZ2 2 4,PKZ2 ZM 6 PKZ2 A B ZM 6 PKZ2 3 4. Device is not approved by UL or CSA,Once inserted coding pins are not removable. STARTER CAT NA 0708,Discount Code A31 moellerNA com C51. C Manual Motor Controllers STARTER CAT NA 0708 moellerNA com C47 Manual Motor Controllers Overview PKZ2 PKZ2 Manual Motor Controllers Overview Device Description