Transcription:

Safety Instructions, Please read the instructions carefully before using the equipment. To use the equipment correctly do not attempt to install operate maintain or inspect the equipment until. you have read through this Instruction Manual Installation guide and appended documents carefully Do not. use the equipment until you have a full knowledge of the equipment safety information and instructions. In this Instruction Manual the safety instruction levels are classified into WARNING and CAUTION. Indicates that incorrect handling may cause hazardous conditions. WARNING resulting in death or severe injury, Indicates that incorrect handling may cause hazardous conditions. CAUTION resulting in medium or slight injury to personnel or may cause physical. Note that the CAUTION level may lead to a serious consequence according to conditions. Please follow the instructions of both levels because they are important to personnel safety. What must not be done and what must be done are indicated by the following diagrammatic symbols. Indicates what must not be done For example No Fire is indicated by. Indicates what must be done For example grounding is indicated by. In this Instruction Manual instructions at a lower level than the above instructions for other functions and so. on are classified into POINT, After reading this Instruction Manual keep it accessible to the operator. 1 To prevent electric shock note the following, Before wiring and inspections turn off the power and wait for 15 minutes or more until the charge lamp. turns off Then confirm that the voltage between P and N is safe with a voltage tester and others. Otherwise an electric shock may occur In addition when confirming whether the charge lamp is off or. not always confirm it from the front of the servo amplifier. Ground the servo amplifier and servo motor securely. Any person who is involved in wiring and inspection should be fully competent to do the work. Do not attempt to wire the servo amplifier and servo motor until they have been installed Otherwise it. may cause an electric shock, Do not operate switches with wet hands Otherwise it may cause an electric shock.
The cables should not be damaged stressed loaded or pinched Otherwise it may cause an electric. During power on or operation do not open the front cover of the servo amplifier Otherwise it may cause. an electric shock, Do not operate the servo amplifier with the front cover removed High voltage terminals and charging. area are exposed and you may get an electric shock. Except for wiring and periodic inspection do not remove the front cover of the servo amplifier even if the. power is off The servo amplifier is charged and you may get an electric shock. To prevent an electric shock always connect the protective earth PE terminal marked of the servo. amplifier to the protective earth PE of the cabinet. To avoid an electric shock insulate the connections of the power supply terminals. 2 To prevent fire note the following, Install the servo amplifier servo motor and regenerative resistor on incombustible material Installing. them directly or close to combustibles will lead to smoke or a fire. Always connect a magnetic contactor between the power supply and the main circuit power supply L1. L2 and L3 of the servo amplifier in order to configure a circuit that shuts down the power supply on the. side of the servo amplifier s power supply If a magnetic contactor is not connected continuous flow of a. large current may cause smoke or a fire when the servo amplifier malfunctions. Not doing so may cause a fire when a regenerative transistor malfunctions or the like may overheat the. regenerative resistor, Always connect a molded case circuit breaker or a fuse to each servo amplifier between the power. supply and the main circuit power supply L1 L2 and L3 of the servo amplifier in order to configure a. circuit that shuts down the power supply on the side of the servo amplifier s power supply If a molded. case circuit breaker or fuse is not connected continuous flow of a large current may cause smoke or a. fire when the servo amplifier malfunctions, When using the regenerative resistor switch power off with the alarm signal. Provide adequate protection to prevent screws and other conductive matter oil and other combustible. matter from entering the servo amplifier and servo motor. 3 To prevent injury note the following, Only the voltage specified in the Instruction Manual should be applied to each terminal Otherwise a.
burst damage etc may occur, Connect cables to the correct terminals Otherwise a burst damage etc may occur. Ensure that polarity is correct Otherwise a burst damage etc may occur. The servo amplifier heat sink regenerative resistor servo motor etc may be hot while the power is on. and for some time after power off Take safety measures such as providing covers to avoid accidentally. touching them by hands and parts such as cables,4 Additional instructions. The following instructions should also be fully noted Incorrect handling may cause a fault injury electric. shock fire etc,1 Transportation and installation, Transport the products correctly according to their mass. Stacking in excess of the specified number of product packages is not allowed. Do not hold the front cover when transporting the servo amplifier Otherwise it may drop. Install the servo amplifier and the servo motor in a load bearing place in accordance with the Instruction. Do not get on or put heavy load on the equipment, The equipment must be installed in the specified direction. Leave specified clearances between the servo amplifier and the cabinet walls or other equipment. Do not install or operate the servo amplifier and servo motor which have been damaged or have any. parts missing, Do not block the intake and exhaust areas of the servo amplifier Otherwise it may cause a malfunction.
Do not drop or strike the servo amplifier and servo motor Isolate them from all impact loads. When you keep or use the equipment please fulfill the following environment. Items Environment,Ambient Operation 0 C to 55 C non freezing. temperature Storage 20 C to 65 C non freezing,Ambient Operation. 90 RH or less non condensing,humidity Storage, Ambience Indoors no direct sunlight free from corrosive gas flammable gas oil mist dust and dirt. Altitude 2000 m or less above sea level Contact your local sales office for the altitude for options. Vibration resistance 5 9 m s2 at 10 Hz to 55 Hz directions of X Y and Z axes. When the equipment has been stored for an extended period of time contact your local sales office. When handling the servo amplifier be careful about the edged parts such as corners of the servo. The servo amplifier must be installed in the metal cabinet. When fumigants that contain halogen materials such as fluorine chlorine bromine and iodine are used. for disinfecting and protecting wooden packaging from insects they cause malfunction when entering our. products Please take necessary precautions to ensure that remaining materials from fumigant do not. enter our products or treat packaging with methods other than fumigation heat method Additionally. disinfect and protect wood from insects before packing products. Wire the equipment correctly and securely Otherwise the servo motor may operate unexpectedly. Do not install a power capacitor surge killer or radio noise filter FR BIF H option on the servo. amplifier output side, To avoid a malfunction connect the wires to the correct phase terminals U V and W of the servo. amplifier and servo motor, Connect the servo amplifier power output U V and W to the servo motor power input U V and W.
directly Do not let a magnetic contactor etc intervene Otherwise it may cause a malfunction. Servo amplifier Servo motor Servo amplifier Servo motor. The connection diagrams in this instruction manual are shown for sink interfaces unless stated. The surge absorbing diode installed to the DC relay for control output should be fitted in the specified. direction Otherwise the emergency stop and other protective circuits may not operate. Servo amplifier Servo amplifier,24 V DC 24 V DC,DOCOM DOCOM. Control output RA,Control output RA,signal signal, For sink output interface For source output interface. When the cable is not tightened enough to the terminal block the cable or terminal block may generate. heat because of the poor contact Be sure to tighten the cable with specified torque. Connecting a servo motor for different axis to the U V W or CN2 may cause a malfunction. Configure a circuit to turn off EM2 or EM1 when the main circuit power is turned off to prevent an. unexpected restart of the servo amplifier,3 Test run and adjustment. Before operation check the parameter settings Improper settings may cause some machines to perform. unexpected operation, Never adjust or change the parameter values extremely as it will make operation unstable. Do not close to moving parts at servo on status, Provide an external emergency stop circuit to ensure that operation can be stopped and power switched.
off immediately,Do not disassemble repair or modify the equipment. Before resetting an alarm make sure that the run signal of the servo amplifier is off in order to prevent a. sudden restart Otherwise it may cause an accident, Use a noise filter etc to minimize the influence of electromagnetic interference Electromagnetic. interference may be given to the electronic equipment used near the servo amplifier. Burning or breaking a servo amplifier may cause a toxic gas Do not burn or break it. Use the servo amplifier with the specified servo motor. The electromagnetic brake on the servo motor is designed to hold the motor shaft and should not be. used for ordinary braking, For such reasons as service life and mechanical structure e g where a ball screw and the servo motor. are coupled via a timing belt the electromagnetic brake may not hold the motor shaft To ensure safety. install a stopper on the machine side,5 Corrective actions. Ensure safety by confirming the power off etc before performing corrective actions Otherwise it may. cause an accident, When it is assumed that a hazardous condition may occur due to a power failure or product malfunction.
use a servo motor with an electromagnetic brake or external brake to prevent the condition. Configure an electromagnetic brake circuit which is interlocked with an external emergency stop switch. Contacts must be opened when ALM Contacts must be opened with. Malfunction or MBR Electromagnetic the Emergency stop switch. brake interlock turns off,Servo motor,Electromagnetic brake. When any alarm has occurred eliminate its cause ensure safety and deactivate the alarm before. restarting operation, Provide an adequate protection to prevent unexpected restart after an instantaneous power failure. 6 Maintenance inspection and parts replacement, Make sure that the emergency stop circuit operates properly such that an operation can be stopped. immediately and a power is shut off by the emergency stop switch. It is recommended that the servo amplifier be replaced every 10 years when it is used in general. environment, When using a servo amplifier whose power has not been turned on for a long time contact your local. sales office,7 General instruction, To illustrate details the equipment in the diagrams of this Instruction Manual may have been drawn.
without covers and safety guards When the equipment is operated the covers and safety guards must. be installed as specified Operation must be performed in accordance with this Specifications and. Instruction Manual,DISPOSAL OF WASTE, Please dispose a servo amplifier battery primary battery and other options according to your local laws and. regulations,EEP ROM life, The number of write times to the EEP ROM which stores parameter settings etc is limited to 100 000 If. the total number of the following operations exceeds 100 000 the servo amplifier may malfunction when the. EEP ROM reaches the end of its useful life, Write to the EEP ROM due to parameter setting changes. Write to the EEP ROM due to device changes,Write to the EEP ROM due to point table changes. Write to the EEP ROM due to program changes, Home position setting in the absolute position detection system.
STO function of the servo amplifier, When using the STO function of the servo amplifier refer to chapter 13 of MR J4 A RJ Servo Amplifier. Instruction Manual, For the MR J3 D05 safety logic unit refer to app 5 of MR J4 A RJ Servo Amplifier Instruction Manual. Compliance with global standards, For the compliance with global standards refer to app 4 of MR J4 A RJ Servo Amplifier Instruction. About the manuals, You must have this Instruction Manual and the following manuals to use this servo Ensure to prepare. them to use the servo safely,Relevant manuals,Manual name Manual No.
MELSERVO MR J4 A RJ Servo Amplifier Instruction Manual SH NA 030107. MELSERVO MR J4 A RJ Servo Amplifier Instruction Manual POSITIONING MODE SH NA 030143. MELSERVO MR J4 DU RJ MR CR55K Instruction Manual Note 6 SH NA 030153. MELSERVO J4 Servo Amplifier Instruction Manual Troubleshooting SH NA 030109. MELSERVO Servo Motor Instruction Manual Vol 3 Note 1 SH NA 030113. MELSERVO Linear Servo Motor Instruction Manual Note 2 SH NA 030110. MELSERVO Direct Drive Motor Instruction Manual Note 3 SH NA 030112. A 1 Safety Instructions Please read the instructions carefully before using the equipment To use the equipment correctly do not attempt to install operate

Related Books