Low Energy Hardware Installation Manual With Opus Control

Low Energy Hardware Installation Manual With Opus Control-Free PDF

  • Date:25 Nov 2020
  • Views:5
  • Downloads:0
  • Pages:24
  • Size:1.43 MB

Share Pdf : Low Energy Hardware Installation Manual With Opus Control

Download and Preview : Low Energy Hardware Installation Manual With Opus Control


Report CopyRight/DMCA Form For : Low Energy Hardware Installation Manual With Opus Control


Transcription:

www NabcoEntrances com GT 710 8710 Opus Low Energy Hardware Installation Manual. Rev 5 27 16 Part C 00085,Table of Contents,Warning Labels ii. General Safety Recommendations iii,CHAPTER 1 SCOPE 1 4. Section 1a To the Installer 1 4,Section 1b Objective 1 4. CHAPTER 2 GETTING STARTED 2 5,Section 2a Electrical Standards 2 5. Section 2b Installation Specifications 2 5,Section 2c Base Unit Type 2 5.
Section 2d Handing 2 5,Section 2e Swing Door Types 2 6. Section 2f Simultaneous Pair Installations 2 7,Section 2g Associated Manuals Part Numbers 2 7. CHAPTER 3 INSTALL THE HEADER 3 8,Section 3a Before Installing the Header 3 8. Section 3b Prepare the Header 3 8,Section 3c Prepare the Door Frame 3 9. Section 3d Install the Shim Metal Door Frames 3 10. Section 3e Secure the Header to the Door Frame 3 11. CHAPTER 4 120 VAC GENERAL WIRING 4 12, CHAPTER 5 INSTALL THE OUTSWING ARM SHOE ASSEMBLY 5 13.
Section 5 a Prep the Door 5 13, Section 5 b Prep and Secure the Outswing Arm Shoe Assembly 5 14. CHAPTER 6 INSTALL THE INSWING ARM TRACK 6 16, Section 6 a Prep the Door for Inswing Arms with Reveal 6 16. Section 6 b Prep the Door for Inswing Arms with Zero Reveal 6 17. Section 6 c Secure the Track to the Swing Door 6 17. CHAPTER 7 INSTALL THE SWING ARM 7 18,Section 7 a Set Pre Load 7 18. Section 7 b Secure the Swing Arm to the Swing Door 7 19. Section 7 c Install the Arm Stop 7 20,CHAPTER 8 ADJUSTMENTS 8 21. Section 8a Adjust Opening Closing Force on LCN Tension Spring 8 21. Section 8b Adjust Latch Speed 8 22,Section 8c Adjust Back Check Speed 8 22.
CHAPTER 9 TROUBLESHOOTING 9 23, GT 710 8710 Opus Low Energy Hardware Installation Manual www NabcoEntrances com. Part C 00085 Rev 5 27 16,WARNING LABELS, Warning labels are universal and used to alert an individual of potential harm to one s self or to others The following warning. labels are listed in a hierarchy order that defines the most potential danger first and the least potential danger last Please refer. to this page in the event that a warning label is displayed within this manual and further definition needs to be explained. DANGER Indicates potentially dangerous situations Danger is used when there is a hazardous. situation where there is a high probability of severe injury or death It should not be. considered for property damage unless personal injury risk is present. WARNING Indicates a hazardous situation which has some probability of severe injury. It should not be considered for property damage unless personal injury risk. is present, CAUTION Indicates a hazardous situation which may result in a minor injury Caution should not. be used when there is a possibility of serious injury Caution should not be considered for. property damage accidents unless a personal injury risk is present. Attention A situation where material could be damaged or the function impaired. Notice Indicates a statement of company policy as the message relates to the personal. safety or protection of property Notice should not be used when there is a hazardous. situation or personal risk, Note Indicates important information that provides further instruction. www NabcoEntrances com GT 710 8710 Opus Low Energy Hardware Installation Manual. Rev 5 27 16 Part C 00085,GENERAL SAFETY RECOMMENDATIONS.
WARNING Read this General Safety Recommendations section before installing operating or. servicing the automatic door Failure to follow these practices may result in serious. consequences, Notice Read study and understand the operating instructions contained in or referenced. in this manual before operating If you do not understand the instruction ask the. installing qualified technician to teach you how to use the door. WARNING Do not install operate or service this product unless you have read and understand the. General Safety Recommendations Warning Labels Installation and Operating Instructions. contained in this manual Failure to do so may result in bodily injury or property damage. Notice This manual and the owner s manual must be given to and retained by the purchasing. facility or end user, If the door appears broken or does not seem to work correctly it should be immediately. removed from service until repairs can be carried out or a qualified service technician is. contacted for corrective action, Disconnect power at the fused disconnect during all electrical or mechanical service When. uncertain whether power supply is disconnected always verify using a voltmeter. All electrical troublshooting or service must be performed by qualified electrical technicians. and must comply with all applicable governing agency codes. It is the responsibility of the installing door technician to install all warning and instructional. labels in accordance with ANSI 156 19, It is the responsibility of the purchasing facility or end user to keep warning and. instructional labels and literature legible intact and with the door. Replacement labels and literature may be obtained from local NABCO Entrances Inc. distributors If the name of the local distrubutor is unknown contact NABCO Entrances Inc. at 1 877 622 2694 for assistance, DANGER Do not place finger or uninsulated tools inside the electrical controller Touching wires or.
other parts inside the enclosure may cause electrical shock serious injury or death. GT 710 8710 Opus Low Energy Hardware Installation Manual www NabcoEntrances com. Part C 00085 Rev 5 27 16,CHAPTER 1 SCOPE,Section 1a To the Installer. The purpose of this manual is to familiarize the installer and purchaser with the proper installation and. operation of this system It is essential that this equipment be properly installed and operational before. the door is used by the public It is the installer s responsibility to inspect the operation of the entrance. system to be sure it complies with any applicable standards In the United States ANSI Standard 156 19. ANSI Standard 117 1 and the Low Energy Operator section of ADA Standard covers the GT 710 8710. Swing Door Low Energy System Other local standards or codes may apply Use them in addition to. the ANSI standard Low Energy Swing door Units are listed with the Underwriters Laboratory and is. identified as such on the label, The owner should determine the door is operating properly and should immediately call for service if. there is any malfunction All installation changes and adjustments must be made by qualified NABCO. trained technicians, If after troubleshooting a problem a satisfactory solution cannot be achieved please call Nabco Entrances. at 1 877 622 2694 between 8 am 4 30 pm Central time for additional assistance. WARNING Turn OFF all power to the Automatic Door if a Safety System is not working. Instruct the Owner to keep all power turned OFF until corrective action can be. achieved by a NABCO trained technician Failure to follow these practices may result in. serious consequences, NEVER leave a Door operating without all Safety detection systems operational. Section 1b Objective, GT 710 8710 Swing Door Low Energy Units are designed to be installed onto the top surface of the Door.
Frame The Operator is controlled by the Opus Control that offers many features to accommodate most. installation options This manual offers step by step instructions. www NabcoEntrances com GT 710 8710 Opus Low Energy Hardware Installation Manual. Rev 5 27 16 Part C 00085,CHAPTER 2 GETTING STARTED. Section 2a Electrical Standards, Note It is recommended for the Installer to use an Electrical Conduit to house all incoming 120 VAC wires. Note All wiring must conform to standard wiring practices and be in accordance with national and local. electrical codes,Electricity Description Current Consumption. Power Input 110VAC 130 VAC AC 50 60 Hz 3A NABCO recommends min 5A service. Available Current for accessories 12 VDC 750mA,F1 Fuse 120VAC Power Circuit of Control. Available wire size for incoming power 14 AWG,Section 2b Installation Specifications.
Specification Measurement,Minimum Frame Face for Mounting 1 3 4 inches 44mm. Minimum Clearance from Top of Door to Ceiling 7 178 mm. Door Hinge Requirements 3 4 inch Butt Offset Pivot or Center Pivot. Minimum Door Thickness 1 3 4 inches 44 mm,Door Width Specified when ordered. Section 2c Base Unit Type,XX Side Load Header only. XX Low Energy Swing doors utilize a Knowing Act to open a Swing door. A conscious effort that is carried out in many different ways including but not limited to. manually opening closing a Swing door pressing various types of Push Plates turning a Key. switch flipping a Rocker Switch utilizing a keypad or card reader etc. XX Must be compliant with the ANSI Standard Code 156 19 to reduce chance of injury to pedestrians and. wheeled traffic,Section 2d Handing, XX To Determine Handing from the Operator go to the top of the LCN Door Closer The letter R or L. will be marked on the Shaft by the NABCO Factory Please see Figure 2 1. L for Le R for Right Sha,LCN Door Closer,Figure 2 1 Handing Labeled.
Getting Started 2 5, GT 710 8710 Opus Low Energy Hardware Installation Manual www NabcoEntrances com. Part C 00085 Rev 5 27 16, XX To determine Handing from standing underneath the Header Open the Swing door Butt your back. against the Pivot side of Swing door Swing out the right or left arm in the direction the Swing door. opened Please see Figure 2 2,RIGHT HANDING,Pivot S le on Swing Door Swing Door. DN 1049 LEFT HANDING, Figure 2 2 Stand with back against Pivot Side of Swing door. XX To determine Handing from the direction the Swing Arm opens Please see Figure 2 3. a If the Swing Arm swings underneath the Threshold to open it is an Outswing Unit. b If the Swing Arm does not swing underneath the Threshold to open it is an Inswing Unit. INSWING INSWING,LEFT HAND RIGHT HAND,Arm Moun ng Bracket.
Inswing Track,OUTSWING OUTSWING,RIGHT HAND LEFT HAND. DN 1055 Threshold EXTERIOR SIDE OF DOOR,Figure 2 3 Determine Handing. Section 2e Swing Door Types,Inswing Inswing,Single Single. Le Hand Right Hand,IN IN Simultaneous Simultaneous. Outswing Pair Inswing Pair,OUT OUT OUT OUT,Outswing Outswing.
Single Single,Right Hand Le Hand,IN IN IN IN,Dual Inswing Dual Inswing. DN0461 OUT OUT Outswing Pair OUT OUT Outswing Pair. 2 6 Getting Started, www NabcoEntrances com GT 710 8710 Opus Low Energy Hardware Installation Manual. Rev 5 27 16 Part C 00085,Section 2f Simultaneous Pair Installations. Simultaneous pair doors require two operators two motors two control boards and a simultaneous. pair harness All drilling and mounting dimensions for simultaneous pair doors should use both the left. and right hand patterns for the specific swing direction and hinge configuration The installer first has to. configure each control independently of the other control Once controls are tuned individually connect. the simultaneous pair harness to both controls and fine tune simultaneous pair operation. Section 2g Associated Manuals Part Numbers, XX Model GT710 8710 Low Energy Swing Doors Quick Setup Parts Guide P N C 00178. XX Opus Control Wiring and Programming Manual P N 15 14973. XX Model GT500 GT710 Low Energy Owner s Manual P N C 00125 for Decal Installation. XX NABCO Price Book P N 16 9244 30 for Sensors Switches and Accessories. Getting Started 2 7, GT 710 8710 Opus Low Energy Hardware Installation Manual www NabcoEntrances com.
Part C 00085 Rev 5 27 16,CHAPTER 3 INSTALL THE HEADER. Section 3a Before Installing the Header,1 Open the Inswing door 90 degrees. a Outswing doors do not need to be measured, 2 Measure between the wall and the outside face of the Swing Door. a There must be a 2 inch minimum gap, b If there is less than a 2 inch gap please call Customer Service at 877 622 2694. Space between Building Wall,and Face of Door must be at.
least 2inches or more,Building Wall,Figure 3 1 Inswing Door Gap. Section 3b Prepare the Header, Note It may be necessary to remove the Motor Operator from the Header to reduce weight while positioning. the Header onto the Door Frame,1 Remove the Header Cover Please see Figure 3 2. 2 Remove boxes and or parts bags from inside Header. Cover in Closed Posi on UP Li UP to,to Open Pull out. GT 8710 Header,Remove Screws,GT 710 Header,Figure 3 2 Remove Cover from Header.
3 b a Drill Holes in Header GT8710, Note Protect Header Components from metal chips when drilling. 1 Go to the Strike side of Header Drill one 7 8 inch hole through the Header to allow all wiring to be. drawn inside, a The GT 8710 Header can be ordered with a Knockout hole located at either end of the Header For. details please call Customer Service at 1 888 679 3319. b For Simultaneous Pair Swing Doors a 7 8 inch hole can be drilled in back of the header. 3 8 Install the Header, www NabcoEntrances com GT 710 8710 Opus Low Energy Hardware Installation Manual. Rev 5 27 16 Part C 00085, 2 Go to the back wall inside Header on the Pivot side. 3 Measure 1 inch from the End Cap of Header towards the center Mark a Vertical Line Please see. Figure 3 3, 4 Measure at least 1 2 inch from the bottom of Header towards the top Mark a Horizontal Line across.
the Vertical line This is the center of the first screw hole Drill 1 4 inch screw hole. 5 Mark 1 more Horizontal line across the Vertical line directly above the first screw hole This is the. Low Energy Hardware Installation Manual With Opus Control Side Load Units GT 710 and 8710 DN 1078 GT710 SIDE LOAD UNIT Hinged Side Access Panel GT8710 SIDE LOAD UNIT Hinged Side Access Panel WARNING Turn OFF all power to the Automatic Door if a Safety System is not working Instruct the Owner to keep all power turned OFF until corrective action can be achieved by a NABCO trained

Related Books