ROTARY SWITCH,THE ADVANTAGE IS YOURS, KAYCEE Rotary Switches have been engineered with reliable design especially to meet the requirements. of latest concept for switching technology in control engineering and thus offer complete design flexibility. to assemble complex switching program, These are guarantee for optimum performance and meet with latest industrial application. Also backed by the industries most knowledgeable and responsive engineering and customer service. professionals, Assembled on packet principle with choice of four position and multi pole circuits The superior. engineering materials and manufacturing processes for rotary switch components ensure reliable. electrical endurance for safer operation and used for longer life The high grade engineering plastics for. the components ensure greater mechanical strength,APPLICATION FEATURES. Making breaking circuits Design assembled on packet principle. Isolation of power circuits Air break type Wiping contact. Switching of auxiliary circuits Make before break contact. Motor application 90 angle of throw, Ammeter or Voltmeter Selector Switches Panel base mounting.
Unwanted position blocked when specified, RANGE With high grade thermo plastics with excellent electrical properties. Tested at ERDA as per IEC 60947 Part I III 2005,16A 250V AC 10A 440V AC CE marking. 25A 250V AC 16A 440V AC Factory ISO 9001 2008 certified by UL DQS Inc USA. 16A 440V AC Operating mechanism slow break Principally for AC switching only. 25A 440V AC Kaycee rotary switches comply with IS 13947 Part I III. ELECTRICAL DATA,Continuos Current 10A 16A 25A,Operational Voltage 250V 440V AC. High Voltage Test 2 5 Kv for 1 minute,Ambient Temperature upto 50 C. Mechanical Life 1 Lakh operation,Electrical Life Depends upon the application.
Short Time Withstand Current 10 Times of operating current for 1 Sec. Short Time Making Breaking Capacity 10 Times of operating current. ROTARY SWITCH,CODING SYSTEM, Rotary Switches consist of index letters figures grouped in sequence to indicate. the salient features of the switches,SRP1817A MB TB3 LG1 GC. A Prefix letters S indicates AC only slow break quick make mechanism. B The next Group of letters Method of Mounting,RP Back up panel flush mounting. BC Front of panel base mounting,X Universal mounting. M Indicates switch for three phase 440V, C The next Group of figures Indicates Current rating.
1 10 A 16 A,D The next Group of figures Indicates No of poles. 8 No of Poles,E The next Group of figures Indicates No of disc. 17 No of discs in switches assembly,F Suffix letters Indicates switches sequence. Note ON OFF Switches have no suffix letters,A 2 way no off. B 2 way with off,C 3 way with off,D 4 way no off,Motor Control Switches.
BX 34 Star delta starting with off,AB 65 Two speeds with off High or low. LK Reversing or polarity change over no off forward reverse. K Reversing or polarity chage over with off,G Special codes VS Voltmeter selector switch. MA60 Ammeter selector switch,PC Speed control switch. MB Make before break contact,PD Pad locking,H Blocking Mechanism For 4 position switch. TA indicates switch limited to 3 operating position. TB indicates switch limited to 2 operating position. TC indicates switch limited to between normal position. I Locking attachment L Lever type lock,T Tee type lock.
P Pistol grip type handle,K Knob type handle,J Centre key lock assembly. Code ref G1 G2 G3 G4 G12 G13 G24 G, Locking Position key position 1 2 3 4 1 2 1 3 2 4 All. K Cubicle door interlock Lockable type,Code ref HR1 HR2 HR3 HR4 HR12 HR13 HR 24 HR. Position in which lock dis engage 1 2 3 4 1 2 1 3 2 4 All. L Cubicle door interlock Non lockable type,Code ref SH1 SH2 SH3 SH4 SH13 Sh24. Position in which lock dis engage 1 2 3 4 1 3 2 4, M Code for indication plate GB Grey flush plate with indicating plate black knob.
YR Yellow flush plate with indicating plate red knob. G Grey flush plate with indicating plate,Y Yellow flush plate with indicating plate. ROTARY SWITCH,CODING FOR LIMITED POSITION SWITCHES 90 SWITCHING. 3 POSITION SWITCH 4 2 4 X 4 2 X 2,CODE TA 3 3 3,TA 1 TA 2 TA 3 TA 4. 2 POSITION SWITCH 4 X 4 X X 2 X 2,CODE TB X 3,TB 1 TB 2 TB 3 TB 4. BETWEEN POSITIONS LIMITING 4 2 4 2,MECHANISM CODE TC 3.
TC 1 TC 2 TC 3 TC 4,MOUNTING DETAILS,1 Remove knob. 2 Remove holder IP background plate,3 Remove two screws M4 x 12. 4 Fit Switch on panel For Mounting holes refer mounting drawing. 5 Fit two screws M4 x 12,6 Fit background plate IP And holder. 7 Fit Knob,ROTARY SWITCH,10 16 25 Amperes 4 Position 90. Rotary Switches of 10 16 and 25 Amp 4 position listed on next page are. with standard switching sequences up to 4 poles Multi pole switches are offered. on request,Open execution without any enclosure, Air break wiping contact Double Break silver plated self aligning.
10 16 25 Amp for working voltage of 250 or 440 for AC switching. SPECIFICATIONS, Rotary Switches conform to IS 13947 Part I and Part III 1993 and to BSS. and Defence specifications, Slow break principally for AC switching only Quick make Break principally for. DC switching Also for AC when easy and quick action is necessary. For switches flush at the back of panel mounting specify SRP or SRPM for AC and. RP or RPM for AC DC For Switches flush at front of panel mounting specify. SBC or SBCM for AC and BC or BCM for AC DC,OPERATING HANDLE. Knob Wing type of black colour red colour,OPTIONAL ACCESSORIES. A selection of accessories and attachment from a wide variety is available viz. Handles Detachable Handles Indication Plates Centre Key Locks Cubicle Door. Interlocks Lockable Non Lockable Pad Locking etc Details available on. It is recommended that switches with large built up should have handle. lockable switches with large built up should have LG lock. INDICATING PLATE,LEVER HANDLE NO1 BALL TYPE HANDLE KNOB RED BLACK.
65 x 65 MM,95 x 95 MM, 75 x 75 MM LEVER HANDLE NO2 PAD LOCK DISC TERMINAL SHROUD. ROTARY SWITCH,STANDARD SWITCHING COMBINATIONS,Suitable for Mounting Flush at the Back of Panel. SINGLE PHASE 250 VOLTS 1 2 poles, ROTORY SWITCHES THREE PHASE 440 VOLTS 3 Poles above. 10 16 25 Amperes 4 Position 90 working Voltage 250 to earth. NO OF 10 AMP AC 16 AMP AC 25 AMP AC,POLES TYPE Dim Y TYPE Dim Y TYPE Dim Y. 1 SRP112 17 SRP213 23,OFF 2 SRP123 23 SRP225 35,ON ON 3 SRP134 29 SRPM134 29 SRPM237 47.
4 SRP145 35 SRPM145 35 SRPM249 59,TWO WAY 1 SRP113A 23 SRP213A 23. NO OFF 1 2 SRP125A 35 SRP225A 35,2 2 3 SRP137A 47 SRPM137A 47 SRPM237A 47. A 4 SRP149A 59 SRPM149A 59 SRPM249A 59,TWO WAY 1 SRP113B 23 SRP215B 35. WITH OFF 2 SRP125B 35 SRP229B 59,2 1 3 SRP137B 47 SRPM137B 47 SRPM2313B 83. B 4 SRP149B 59 SRPM149B 59,THREE WAY 1 SRP113C 23 SRP215C 35.
WITH OFF 2 SRP126B 41 SRP229C 59,3 1 3 SRP139C 59 SRPM139C 59 SRPM2313C 83. C 2 4 SRP1412C 77 SRPM1412C 77,FOUR WAY 1 SRP113D 23 SRP215D 35. NO OFF 2 SRP126D 41 SRP229D 59,4 2 3 SRP139D 59 SRPM139D 59 SRPM2313D 83. D 4 SRP1412D 77 SRPM1412D 77, For other dimensions refer separate dimension sheet. Indicating plates square size 64 x 64 mm for standard switches and 75 x 75 mm for switches with Locks Interlocks. Single and double Pole Switches are rated 250V If required for 440V in code add M as shown above Dimension Y shown correspondingly. Add GB in code for switches required with grey I P and black knob Alternatively add YR for yellow I P and red knob If either codes are not specified. then we shall book order with GB,ROTARY SWITCH,INSTRUMENT SELECTOR SWITCHES 10 AMPERES.
Rotary Selector Switches are suitable for instruments like Ammeters Voltmeters SPECIFICATIONS. Power Factor Meters etc The design enables to indicate by means of a single Rotary Switches conform to IS 13947 1993 and also Defence. meter the current or the voltage Ammeter Selector Switches are provided with Specifications. make before break contacts to give security against risk of open circuit of the OPTIONAL ACCESSORIES. current transformer secondaries Listed below are standard switches. Open execution without any enclosure, Air break wiping contacts Double Break self aligning. 10 Amp for working voltage of 250V or 440V for AC circuits only. Slow Break principally for AC switching only, For Switches flush at the back of panel mounting specify SRP for switched at the. front of panel base mounting specify SBC,AMMETER SELECTOR. SWITCHING TYPE DIM Y DIAGRAM,Current in each phase B. B R with OFF 4 positions 90 SRP136MA60 41,Y Indicating plate size 65 X 65 mm sq R Y B.
VOLTMETER SELECTOR,OFF Voltage between phase with Y. RB RY OFF 4 positions 90 Indicating plate size SRP135VS 35. YB 65 X 65 mm sq,OFF Voltage between phase and neutral with. BN RN OFF 4 positions 90 SRP115BE18 35,YN Indicating plate size 65 X 65 mm sq R Y B. SPECIAL SELECTOR SWITCHES,With one switch to indicate with one R. OFF Ammeter one Voltmeter Simulaneous, B R Reading of phase current Voltage SRP1310MB28 65.
Y between phases with an OFF position,Indicating plate size 65 X 65 mm sq V1 A2 A1 A2. OFF 4 Pos Ammeter selector switch Direct in, B R line without CT Indicating plate size SRP1313ZZF12 83. Y 65 X 65 mm sq A1, NOTE Add GB in code for switches required with grey flush plate and black knob Alternatively add YR for Yellow flush plate. and red knob If either codes are not specified then we shall book order with GB. ROTARY SWITCH,PANEL MOUNTING,FLUSH PLATE KNOB M4 NUT FOR MOUNTING. COLOUR YELLOW Y COLOUR RED R AT 25 P C D,OR GREY G OR BLACK B.
4 HOLES 5 HOLES 8,AT 25 P C D,Y 25 13 23 4 HOLES 5 5 SQ 64 00. PANEL DRILLING PLAN,BACK OF PANEL KNOB REMOVED,BASE MOUNTING. 2 HOLES 5 5 2 SLOT KNOB,8L x 5 5 W COLOUR RED R,OR BLACK B 12. Y 15 20 23 SQ 50,PANEL DRILLING PLAN,FRONT OF PANEL HANDLE REMOVED. SMALL UNIVERSAL MOUNTING,2 HOLES 5 5 FLUSH PLATE KNOB.
2 SLOT COLOUR YELLOW Y COLOUR RED R,8L x 5 5 W OR GREY G OR BLACK B 12. 4 HOLES 5 HOLES 8,AT 25 P C D,4 HOLES 5 5,Y 28 13 23 SQ 65. PANEL DRILLING PANEL DRILLING,FRONT OF PANEL BACK OF PANEL. ROTARY SWITCH,CENTER KEY LOCK,FLUSH PLATE 75 SQ,COLOUR YELLOW Y COLOUR BLACK B. 2 HOLES 4 HOLE 36,44 5 CRS PANEL DRILLING,BACK OF PANEL.
2 FIXING SCREWS,M3 5 x 25 L HANDLE FLUSH PLATE REMOVED. RAISED C SK HD,CUBICLE DOOR INTERLOCK NON LOCKABLE. 51 FLUSH PLATE 75 SQ,COLOUR YELLOW Y,2 HOLES 5 5 2 SLOT 20 OR GREY G. 8L x 5 5 W 12,COLOUR BLACK B 2 HOLES 4 HOLE 36,PANEL DRILLING. BACK OF PANEL,PANEL DRILLING PLAN,FRONT OF PANEL 2 FIXING SCREWS.
M3 5 x 25 L HANDLE FLUSH PLATE REMOVED,RAISED C SK HD CUBICLE. Y 44 33 61,ROTARY SWITCH,CUBICLE DOOR INTERLOCK LOCKABLE. 51 FLUSH PLATE 75 SQ,COLOUR YELLOW Y,2 HOLES 5 5 2 SLOT 20 OR GREY G. 8L x 5 5 W,COLOUR BLACK B,2 HOLES 4 HOLE 36,PANEL DRILLING. BACK OF PANEL,PANEL DRILLING,FRONT OF PANEL 2 FIXING SCREWS.
M3 5 x 25 L,RAISED C SK HD CUBICLE,Y 44 33 57,PAD LOCK SWITCH. PAD LOCK DISC NO 1 PAD LOCK DISC NO 2,COLOUR YELLOW Y COLOUR RED R. 4 HOLES 5 4 HOLES 5,AT 25 P C D AT 50 P C D,Y 25 43 HOLES 8 SQ 65. PANEL DRILLING PLAN,BACK OF PANEL,ROTARY SWITCH,ORDER FORMAT. APPLICATION AC OR AC DC CURRENT VOLTAGE, MOUNTING a PANEL b BASE c UNIVERSAL TERMINAL ACCESSIBLE a FRONT b BACK.
NO OF POLES SWITCH TYPE, TYPE OF CONTRACTS BREAK BEFORE MAKE OR MAKE BEFORE BREAK. NO OF POSITION S BLOCKED POSITION S, TYPE OF HANDLE a WING TYPE b BALL TYPE c PISTOL GRIP. d LEVER TYPE e CAPSTAN TYPE, CENTRE KEY LOCK a LEVER TYPE LG b TEE TYPE TG c CAPSTAN TYPE CG. ONLY FOR 4 POS SWITCHES,LOCKING POSITION S, CUBICAL DOOR INTERLOCK a LEVER TYPE LSH FOR 10 60 AMPS. NON LOCKABLE TYPE 100 600 AMPS AND 100 AMPS LIGHT DUTY 4 POSITION ONLY. b CAPSTAN TYPE CSH FOR 100 600 AMPS, CUBICAL DOOR INTERLOCK a LEVER TYPE LHR FOR 10 60 AMPS AND.
100 AMPS LIGHT DUTY 4 POSITION ONLY,b CAPSTAN TYPE CHR FOR 100 600 AMPS. INDICATING PLATE MARKINGS POS 1 POS 5,POS 2 POS 6,POS 3 POS 7. POS 4 POS 8,MAIN LABEL OF INDICATING PLATE, FOR PROGRAMME OTHER THAN LISTED ATTACH YOUR PROGRAMME SHEET WITH ORDER. ONLY FOR 100 600 AMPS SWITCHES ONLY, PAD LOCKING ALSO AVAILABLE FOR 10 60 AMPS 4 POSITION SWITCHES. SPECIFY POSITION S IN WHICH THE DOOR INTERLOCK SHOULD DISENGAGE. SPECIFY POSITION S IN WHICH THE DOOR INTERLOCK SHOULD DISENGAGE. AND ALSO LOCK THE HANDLE, 10 60 AMPS AND 100 AMPS LIGHT DUTY SWITCHES WILL BE SUPPLIED WITH BLACK KNOB AND GREY.
FLUSH PLATE AND ACRYLIC INDICATING PLATE GB IF SPECIFY CAN BE SUPPLIED WITH YELLOW. FLUSH PLATE AND ACRYLIC INDICATING PLATE AND RED KNOB. 100 600 AMPS SWITCHES UPTO 3 DISC WILL BE SUPPLIED WITH LEVER HANDLE ABOVE 3 DISC. CAPSTAN TYPE HANDLE, 100 600 AMPS SWITCHES WILL BE SUPPLIED WITH ANNODISED ALUMINIUM INDICATING PLATES. Manufactured by,KAYCEE INDUSTRIES LIMITED,32 Ramjibhai Kamani Road Ballard Estate. Mumbai 400 001,Tel 91 22 2261 3521 22 23,Fax 91 22 2261 6106. E mail kayceeindltd vsnl com,Website www kayceeindustries com. Authorised Channel Partner,Branch Offices,Ahmedabad 096240 64739 Kolkata 093392 00968.
Bangalore 093428 53324 Nashik 098506 66743,Chennai 093812 01556 Pune 098222 51408. KAYCEE Rotary Switches have been engineered with reliable design especially to meet the requirements of latest concept for switching technology in control engineering and thus offer complete design flexibility to assemble complex switching program These are guarantee for optimum performance and meet with latest industrial application