Operator s Manual, SkyAz l makes no warranty of any kind with regard to this material including but not limited to. the implied warranties of merchantability and or its fitness for a particular purpose. SkyAz l will not be liable for errors contained in this manual or for incidental or consequential. damages in connection with the furnishing performance or use of this manual This document. contains proprietary information which is protected by copyright and all rights are reserved. No part of this document may be photocopied reproduced or translated to another language. without the prior written consent of SkyAz l, SkyAz l reserves proprietary rights to all drawings photos and the data contained therein The. drawings photos and data are confidential and cannot be used or reproduced without the. written consent of Hirschmann The drawings and or photos are subject to technical. modification without prior notice, All information in this document is subject to change without notice. MANUAL REVISIONS,REV DATE NAME DESCRIPTION,08 09 13 SC iFLEX E5 1 Operator s Manual SkyAz l. For XCMG QUY220 QUY250 QUY260 QUY280 QUY300,SkyAz l Inc.
16 Walnut Street,Middletown MD 21769,Fax 301 371 0029. info skyazul com, SkyAz l Equipment Solutions www skyazul com 301 371 6126. iFLEX E5 1 Load Moment Indicator, SkyAz l Equipment Solutions www skyazul com 301 371 6126. Operator s Manual iFLEX E5 1 Load Moment Indicator. Table of content,1 GENERAL INFORMATION 2,2 IMPORTANT NOTES 3. 3 SYSTEM CONFIGURATION 4,3 1 I FLEXE5 1 CONTROLLER 5.
3 2 IFLEX C CONTROLLER OPTIONAL 6,3 3 IK2001 CONSOLE 7. 3 4 FORCE SENSOR 8,3 4 1 Technical Data 8,3 4 2 Installation 8. 3 5 WG SERIES ANGLE SENSOR 9,3 5 1 Technical datas 9. 3 5 2 Installation 9,3 6 DAVS PRESSURE TRANSDUCER OPTIONAL 10. 3 6 1 Technical data 10,3 6 2 Installation 10,3 7 ANTI TWO BLOCK SWITCH 11.
3 7 1 Technical data 11,3 7 2 Installation 11,3 8 WIND TRANSMMITTER OPTIONAL 12. 4 DISPLAY AND INTERFACE 13,4 1 STATUS DISPLAY 14,4 2 IMAGE AREA VALUES ARE NOT REAL 15. 4 3 FUNCTION KEY SYMBOLS 17,4 3 FUNCTION KEYS 17,5 OPERATING METHOD VALUES ARE NOT REAL 18. 5 1 OM AND REEVING SETUP 19,5 1 1 OM code information 20. 5 1 2 Numerical OM code setup 20,5 1 3 Geometrical OM setup 21.
5 1 4 Reeving setup 21,5 2 SYSTEM INFORMATION 22,5 2 1 Signal overviwe 22. 5 2 2 Load chart information 24,5 2 3 Error code information 25. 5 2 4 CAN bus status overview 25,5 3 DISPLAY SETUP 26. 5 3 1 Time setting 26,5 3 2 Brightness adjusting 27. 5 3 3 Metric unit Imperial unit selection 27,5 3 4 Chinese English language selection 27.
6 INSPECTION MAINTENANCE AND CONSIDERATIONS 28,6 1 INSPECTION BEFORE OPERATION 28. 6 2 ROUTINE MAINTENANCE 28,6 3 ROUTINE CONSIDERATION 28. 6 4 BUZZER ALARMS 28,6 5 ANGLE SENSOR ADJUSTMENT 28. 7 TROUBLE SHOOTING 29, SkyAz l Equipment Solutions www skyazul com 301 371 6126. Operator s Manual iFLEX E5 1 Load Moment Indicator. 1 General Information, The Hirschmann load moment indicator herein refer to LMI iFLEX E5 1 and control.
system are designed for all types of mobile cranes. The iFLEX E5 1 can provide the crane operator with important information necessary. for the operation of the crane within the areas of operation specified by the manufacturer. The LMI uses a variety of different sensors to monitor different crane functions and. communicates the crane performance data to the crane operator on a continuous basis. This data changes constantly in connection with the crane movements. The LMI provides the operator with the information of the length and angle of the boom. tip height working radius rated load and the actual load weight and so on. If the crane nears its safe load limit the system will warn the crane operator by means. of both acoustic and optical signals In addition as soon as the crane reaches an. unauthorized operating status all crane movements will be switched off that would increase. the load moment on the crane, This manual only introduced the operating method of the LMI Details of the crane. operating standards please refer to the crane operating manual provided by the crane. manufacturers, This manual is for XMGC QUY220 QUY250 QUY260 QUY280 QUY300 crawler crane. Please read it carefully before starting the operation and take the actual crane console. display as standard, SkyAz l Equipment Solutions www skyazul com 301 371 6126. Operator s Manual iFLEX E5 1 Load Moment Indicator. 2 Important Notes, The LMI control system is an assistant collocation for safe operation that warns a machine. operator of approaching overload conditions and of over hoist conditions that could cause. damage to equipment and personnel, The device is not and shall not be a substitute for good operator judgment experience.
and use of accepted safe machine operating procedures. Safe operation is the responsibility for every machine operator Every machine. operator must ensure that they read all warnings and instructions carefully and fully. understand Correct operation depends on daily careful checking and serious study of. the Manual, The LMI is not able to provide aid to the machine operator unless it has been properly. adjusted and unless the correct load capacity chart and the correct operating code. have been entered for the respective rigging configuration The correctness of the SLI. settings must be guaranteed before beginning machine work in order to avoid damage. to property and severe or even fatal injuries to personnel. If you SLM in use fails or is not functioning properly please do stop the operation of the. crane and contact expert service engineer SkyAul does not. assume any responsibility for undesirable consequences resulted from this continued. SkyAzul shall not be liable for damages caused by welding crane without power off the. controller, SkyAz l Equipment Solutions www skyazul com 301 371 6126. Operator s Manual iFLEX E5 1 Load Moment Indicator. 3 System Configuration,System configuration graph, The LMI and control system consist of an iFLEX E5 1 central unit an iSCOUT expert 2001. console and various sensors for recording the measured values. The system operates on the principle of reference real comparison The actual value is. compared with the calculated reference values and evaluated by the system An overload. warning signal is triggered on the display and operating console once limit values are. reached All machine movements that increase the load moment are switched off at the. The crane specific data specified by the manufacturer such as load capacity charts boom. weights centers of gravity and dimensions are stored in the central data memory This. data is the reference information used to calculate the operating conditions. The boom angle is measured by means of angle sensors that are mounted on the boom. The crane load is determined indirectly with the aid of force transducers. SkyAz l Equipment Solutions www skyazul com 301 371 6126. Operator s Manual iFLEX E5 1 Load Moment Indicator. 3 1 iFLEXE5 1 Controller, iFLEXE5 1 Controller 32 digit industrial control PLC system and high powered processor. qualify the requirements of harsh environment for all kinds of industrial system iFLEX5 1. module is composed of base board and extended board Customers could choose different. iFLEX5 1 module according to their own needs Each module can be connected by. CANBUS Due to the building block mode the iFLEX5 1 is not only applicable to medium. and small control systems but also to big and complicated control systems. iFLEX E5 1 controller dimension graph,iFLEX E5 1 controller installation graph.
Technical datas,CPU 32BitRISC processor 48MHz, Memory 8MB Flash can upload to16MB Protection class IP67. Field Bus 1 CANopen2 0B 1 SAE J1939, Connection 2 RS232 1 RS485 Operating voltage 10V 30VDC. Operating temperature 30 70 Storing temperature 40 85. SkyAz l Equipment Solutions www skyazul com 301 371 6126. Operator s Manual iFLEX E5 1 Load Moment Indicator. 3 2 iFLEX C Controller optional, iFLEX C compact class product series are programmable and flexible. configuration of the inputs and outputs The CANopen interface allows the set up of a. decentralized network which offer minimal installation and servicing costs. iFLEX C3 controller dimension graph,Technical data. CPU 16Bit or 32Bit,Protection class IP65,Bus 1 CANopen 1 RS485.
Interface 1 RS232,Operating voltage 10V 36VDC,Anolog input 4 20 mA 0 5V. Operating temperature 20 70,Storing temperature 30 80. SkyAz l Equipment Solutions www skyazul com 301 371 6126. Operator s Manual iFLEX E5 1 Load Moment Indicator. 3 3 IK2001 console, IK2001 console BestVIEW adaptive display can show all the operational data that you. concerned The combination between the Graphical display and Genersys software. achieve the on line program for graph The strong graph compiled capability is. incomparable with other Industrial displays,IK2001console dimension graph. Technical datas,type in dash on dash,housing metal.
protection class front panel IP65 back panel IP65 IP20. Operating voltage 10V 36VDC,Operating temperature 20 70. Storing temperatiure 35 80,Display resolution VGA 640 480. Dimention10 4Zoll diagonal color 256colors,Dimention front panel W H 293 265 9. Section panel dimention W H D 270 232 64, Connection 2 CANopen2 0B 1 Ethernet RS232 RS485 MMC SD Slot. SkyAz l Equipment Solutions www skyazul com 301 371 6126. Operator s Manual iFLEX E5 1 Load Moment Indicator. 3 4 Force sensor, Force sensor is up to shock vibration and electromagnetism resistance standards and has.
simple direct installation and high level of precision The extremely overload capacity and. fatigue limit with low temperature drift and function of temperature compensation makes the. quality never change even in continuous and extreme operation. 3 4 1 Technical Data,Force sensor KMD,Technial data. Accuracy class 0 3,Linearity range 200,Charge of measuring body up to flow Limit. Safe to breaking point 500,Operating temperature 40 70. Protection class IP65 IP67 optional,Operating voltage 10V 30VDC. Housing standless steel,connection M12,3 4 2 Installation.
KMD s are measuring units and require the,conscientious and careful treatment which. is common with all measuring units Be sure,to obtain the fits and tolerances suggested by. Hirschmann or SkyAzul,Observance of the specified installation. situation is the condition for impeccable,measurements. Make sure that no elastic parts are used in,the force transmission as they might affect.
the measurements,The bores in the locking pins must be in. When using self aligning bearings observe,the corresponding clearances. KMD force sensor installation graph, SkyAz l Equipment Solutions www skyazul com 301 371 6126. Operator s Manual iFLEX E5 1 Load Moment Indicator. 3 5 WG series Angle Sensor, WG absolute value angle sensor is simple direct installation and compact and can precisely. measure the angle of boom The sealed housing keeps the inside component away from. infection of temperature humidity etc,3 5 1 Technical datas.
WG angle sensor installation dimension graph,Measuring range WG103 0 90 WG104 0 270. Operating voltage 9 33VDC Output signal current 4 20mA. Linearity tolerance 0 2 Hysteresis tolerance 0 1, Operating temperature 40 85 Storing temperature 40 85. Protection class IP67,3 5 2 Installation, When install an angle sensor the position shall be well considered Generally along the. he foot points of boom to the top direction the angle sensor is installed inside the right. boom foot left location on the contrary it is the right location With no particular. explanation all the angle sensors should be installed on the left location. When install an angle sensor the boom shall be put on an horizontal supporter and. make sure horizontal center of the sensor and the boom are in parallel After the. installation do remember to exam the reliability and security. Foot point of,the boom Angle sensor Horizontal center. line of the boom,Installation graph, SkyAz l Equipment Solutions www skyazul com 301 371 6126.
Operator s Manual iFLEX E5 1 Load Moment Indicator. 3 6 DAVS pressure transducer optional, DAVS pressure transducers measure high static and dynamic pressure values of. liquids or gases in rough operating environment Measuring precision is maintained even. during continuous operation at extremely dynamic pressure The pressure transducer come. with a pressure connector with standardized G1 4 thread. 3 6 1 Technical data,Operating voltage 8 32VDC,Output signal current 4 20mA. CANopen optional,Operating temperature 40 85,Storing temperature 40 100. Protection class IP67,Life expectancy 10million cycles. Hysteresis tolerance 0 1 FS max,DAVS dimension graph.
3 6 2 Installation, Please notice the location of hydraulic piping and valve when install the pressure. transducer By thread connection such as follow graph screw the pressure transducer in. the hydraulic piping or seat of the balancing valves or hydraulic valves. Add the appropriate seal to the interface to prevent oil leakage Guarantee the installation. position is safe considerable and easy for cable connecting. SkyAzl Equipment Solutions www skyazul com 301 371 6126 or SkyAzul 9 3 5 WG series Angle Sensor WG absolute value angle sensor is simple direct installation and compact and can precisely measure the angle of boom The sealed housing keeps the inside component away from infection of temperature humidity etc 3 5 1 Technical datas WG angle sensor installation dimension graph Measuring