Highlife Collection, WATKINS WELLNESS congratulates you on your decision to enjoy the finest spa available. Welcome to the growing family of HOT SPRING spa owners. Before you begin reviewing the manual please take a moment to register your warranty Doing so will assist us in contacting you for any. important product notification, Prior to registering you will need the serial number that is located within the equipment compartment of your HOT SPRING spa. To register please go to http www hotspring com hot tub owners hot tub product warranty registration or simply scan the QR code below. FOR YOUR RECORDS,Spa Model Serial Number,Date Purchased. Cover Serial Number,Accessory Serial Number, If you have any questions about any aspect of your spa s set up operation or maintenance contact your authorized HOT SPRING. dealership They are trained professionals who are familiar with the product as well as new spa ownership concerns Their expertise will. facilitate the enjoyment of your new HOT SPRING spa. IMPORTANT WATKINS WELLNESS reserves the right to change specifications or design without notification and without incurring any. obligation, In most cities and counties permits will be required for the installation of electrical circuits or the construction of exterior.
surfaces decks and gazebos In addition some communities have adopted residential barrier codes which may require. fencing and or self closing gates on the property to prevent unsupervised access to a pool or spa by children under 5 years. Important of age Your HOT SPRING spa is equipped with a locking cover that meets the ASTM F1346 91 Standard for Safety Covers. and as a result is usually exempt from most barrier requirements As a general practice your local Building Department will. inform you of any applicable barrier requirements at the time a permit is obtained for the installation of an electrical circuit. Your HOT SPRING dealer can provide information on which permits may be required. TABLE OF CONTENTS,SAFETY INFORMATION SOVEREIGN MODEL IIN 23. IMPORTANT SAFETY INSTRUCTIONS 1 TRIUMPH MODEL TRHN 24. IMPORTANT SPA INSTRUCTIONS 3 PRODIGY MODEL HN 25,GETTING STARTED JETSETTER LX MODEL JTN 26. SPA FEATURES 4 JETSETTER MODEL JJN 27, QUICK START UP INSTRUCTIONS 5 SPA CARE AND MAINTENANCE. EQUIPMENT COMPARTMENT DOOR 7 DRAIN REFILL INSTRUCTIONS 28. EQUIPMENT COMPARTMENT 7 PREVENTION OF FREEZING 28,WATER QUALITY AND MAINTENANCE FILTER SYSTEM 29. BASIC INFORMATION 8 FILTER CARTRIDGES REMOVAL CLEANING 29. CHEMICAL SAFETY 8 CARE OF THE SPA PILLOWS 29, HOW TO ADD CHEMICALS TO THE WATER 8 CARE OF THE EXTERIOR 30.
FUNDAMENTALS OF WATER MAINTENANCE 9 CARE OF THE SPA COVER 30. THE HOT SPRING SPA WATER MAINTENANCE COVER LIFTER SYSTEM 31. PROGRAM 10,ELECTRICAL REQUIREMENTS,VANISHING ACT INSTRUCTIONS 11. 230 VOLT PERMANENTLY CONNECTED MODELS 32,VACATION WATER CARE INSTRUCTIONS 12. 115 VOLT GFCI PRODIGY JETSETTER JJN 33,WATER TERMINOLOGY 13. 115 VOLT OPERATION 33, OPERATING INSTRUCTIONS 115 230 VOLT CONVERTIBLE MODEL 34. WIRELESS REMOTE CONTROL 14 230 VOLT PRODIGY JETSETTER JJN. HOME SCREEN 14 CONVERSION INSTRUCTIONS 34,TEMPERATURE CONTROL 15 SERVICE INFORMATION.
MEMORY SCREEN 15 GENERAL INFORMATION 36, CLEAN CYCLE SCREEN 15 GFCI AND HIGH LIMIT THERMOSTAT 36. SETTINGS SCREENS 15 NO FAULT HEATER AND INTEGRATED PRESSURE. JETS CONTROL SCREEN 17,SILENT FLO 5000 CIRCULATION PUMP AND. SALT SYSTEM SCREEN OPTIONAL 17 CIRCULATION PUMP THERMAL CUT OFF 36. MUSIC SYSTEM SCREEN OPTIONAL 17 MISCELLANEOUS SERVICE INFORMATION 36. LIGHTS CONTROL SCREEN 18 ACTS INVALIDATING WARRANTY 37. DOCKING TRAY FUNCTION BUTTONS 18 DISCLAIMERS 37,JET MENU WATKINS CUSTOMER SERVICE 37. GRANDEE MODEL GGN 19 TROUBLESHOOTING 37,ENVOY MODEL KKN 20 DOOR PANEL REMOVAL 39. VANGUARD MODEL VVN 21 SPA SPECIFICATIONS 40,ARIA MODEL ARN 22.
Safety Information Do not operate the audio main controls while inside the spa if spa is. equipped with an audio component, Do not connect any auxiliary components for example cable. IMPORTANT SAFETY additional speakers headphones additional audio components to the. audio system unless approved by WATKINS WELLNESS, INSTRUCTIONS Do not self service audio component by opening or removing spa door. panel as this may expose dangerous voltage or other risk of injury. Refer all servicing to qualified service personnel. READ AND FOLLOW ALL Do not attach an external antennae to a spa audio system unless. installed by a licensed electrician in accordance with Article 810 of the. INSTRUCTIONS National Electric Code ANSI NFPA 70, AVOIDING THE RISK TO CHILDREN To reduce the risk of electrical shock replace a damaged cord. DANGER RISK OF CHILD DROWNING immediately Failure to do so may result in death or serious personal. injury due to electrocution, Extreme caution must be exercised to prevent unauthorized access. Your spa is provided with a Ground Fault Circuit Interrupter GFCI. by children To avoid accidents ensure that children cannot use a spa. for user and equipment protection To ensure proper operation of this. unless they are supervised at all times, important safety device test according to the following instructions per.
WARNING electrical configuration, To reduce the risk of injury do not permit children to use this spa unless Cord Connected 115 volt 20 amp models The GFCI is located at. they are closely supervised at all times the end of the power cord Before each use with the unit operating. push the TEST button The unit should stop operating and the GFCI. To reduce the risk of injury lower water temperatures are power indicator will go out Wait 30 seconds and then reset the GFCI. recommended for young children Children are especially sensitive to by pushing the RESET button The GFCI power indicator will turn. hot water on restoring power to the spa If the interrupter does not perform in. Extreme caution must be exercised to prevent unauthorized access this manner there may be an electrical malfunction and with it the. by children To avoid accidents ensure that children cannot use a spa possibility of an electric shock Disconnect the power until the problem. unless they are supervised at all times has been corrected. DO 230 volt permanently installed or converted models. A ground terminal is provided on the terminal block TB 1 system. Make sure you always lock the child resistant locks after using the spa ground terminal located inside the control box To reduce the risk. for your children s safety Every HOT SPRING spa is equipped with of electric shock connect this terminal to the grounding terminal. a locking cover that meets the ASTM F1346 91 Standard for Safety of your electrical service or supply panel with a continuous green. Covers insulated copper wire The wire must be equivalent in size to the. Test the water temperature with your hand before allowing children to circuit conductors supplying the equipment In addition a bonding. enter the spa to be sure that it s comfortable Children are especially terminal pressure wire connector is provided on the outside of the. sensitive to hot water control box for bonding to local ground points To reduce the risk of. Remind children that wet surfaces can be very slippery Make sure electric shock this connector should be bonded with a No 8 AWG. that children are careful when entering or exiting the spa solid copper wire to any metal ladders water pipes or other metal. within 5 feet 1 5 m of the spa to comply with local requirements. DON T The means of disconnection must be readily accessible but must. Allow children to climb onto the spa cover be installed at least 5 feet 1 5 m from the spa. Allow children to have unsupervised access to the spa Your spa is provided with a suitably rated circuit breaker to open all. ungrounded supply conductors, AVOIDING THE RISK OF ELECTROCUTION Your spa uses ground fault circuit interrupters in the electrical. subpanel Before each use of the spa and with the unit operating. DANGER RISK OF ELECTROCUTION push the TEST button on each breaker The switch should click. Connect only to a grounded source over to the Trip position Wait 30 seconds and reset each GFCI. breaker by switching it completely off and then completely on. Do not bury the power cord A buried power cord may result in death The switch should then stay on If either of the interrupters does. or serious personal injury due to electrocution if direct burial type cable not perform in this manner it is an indication of an electrical. is not used or if improper digging occurs malfunction and the possibility of an electric shock Disconnect the. A ground terminal pressure wire connector is provided on the control power until the fault has been identified and corrected. box inside the unit to permit connection of a minimum No 8 AWG IMPORTANT Failure to wait 30 seconds before resetting the GFCI. solid copper bonding conductor between this point and any metal may cause the spa s Power Indicator on the control panel to blink If. equipment metal water pipe metal enclosures of electrical equipment this occurs repeat the GFCI test procedure. or conduit within five feet 1 5 m of the unit as needed to comply with. local requirements,Safety Information Page 1, Persons taking medications which induce drowsiness such as. DANGER RISK OF ELECTRICAL SHOCK tranquilizers antihistamines or anticoagulants should not use the spa. Install at least 5 feet 1 5 m from all metal surfaces A spa may be. installed within 5 feet 1 5 m of a metal surface if each metal surface HEALTH PROBLEMS AFFECTED BY SPA USE. is permanently connected by a minimum No 8 AWG solid copper. conductor attached to the wire ground connector on the terminal. box that is provided for this purpose if in accordance with National Pregnant women should consult a physician before using spa. Electrical Code ANSI NMFPA70 1993 Persons suffering from obesity or with a medical history of heart. Do not permit any electrical appliances such as a light telephone disease low or high blood pressure circulatory system problems or. radio or television within 5 feet 1 5 m of a spa Failure to maintain diabetes should consult a physician before using spa. a safe distance may result in death or serious personal injury due to. electrocution if the appliance should fall into the spa. UNCLEAN WATER, Install your spa is such a way that drainage is away from the electrical. compartment and from all electrical components, Keep the water clean and sanitized with correct chemical care The.
DO recommended levels for your HOT SPRING spa are, Be sure your spa is connected to the power supply correctly use a Free Available Chlorine Total Alkalinity. licensed electrical contractor 1 0 5 0 ppm 40 120 ppm. Disconnect the spa from the power supply before draining the spa or. servicing the electrical components Water pH Calcium Hardness. Test the Ground Fault Circuit Interrupter s before each use 7 2 7 8 Standard 75 150 ppm. Replace audio components only with identical components if your spa Salt System 25 75 ppm. is equipped with an audio component Refer to Water Quality and Maintenance section for complete. DON T instructions, IMPORTANT Turn on the jet pump for a least ten minutes after adding. Use the spa with the equipment compartment door removed. ANY spa water chemicals into the filter compartment. Place electrical appliances within 5 feet 1 5m of the spa. Clean the filter cartridges monthly to remove debris and mineral buildup. Use an extension cord to connect the spa to its power source The which may affect the performance of the hydromassage jets limit the. cord may not be properly grounded and the connection is a shock flow or trip the high limit thermostat which will turn off the entire spa. hazard An extension cord may cause a voltage drop which will cause. overheating of the jet pump motor and motor damage. Attempt to open the electrical control box There are no user serviceable AVOIDING THE RISK OF HYPERTHERMIA. parts inside, Prolonged immersion in hot water can result in HYPERTHERMIA a. RISKS TO AVOID dangerous condition which occurs when the internal temperature of. the body reaches a level above normal 98 6 F 37 C The symptoms. DANGER RISK OF INJURY of hyperthermia include unawareness of impending hazard failure to. perceive heat failure to recognize the need to exit the spa physical. To reduce the risk of injury to persons DO NOT remove suction fittings. inability to exit the spa fetal damage in pregnant women and. filter standpipes located in the filter compartment. unconsciousness resulting in a danger of drowning, The suction fittings in the spa are sized to match the specific water. flow created by the pump Never replace a suction fitting with one WARNING. rated less than the flow rate marked on the original suction fitting The use of alcohol drugs or medication can greatly increase the risk of. There is a danger of slipping and falling Remember that wet surfaces fatal hyperthermia in hot tubs and spas. can be very slippery Take care when entering or exiting the spa. Never operate spa if the suction fittings are broken or missing. TO REDUCE THE RISK OF INJURY, People with infectious diseases should not use the spa.
Keep any loose articles of clothing long hair or hanging jewelry away. The water in the spa should never exceed 104 F 40 C Water. from rotating jets or other moving components, temperatures between 100 F and 104 F 36 C and 40 C are. considered safe for a healthy adult Lower water temperatures are. HIGHLIFE COLLECTION Grandee Envoy Vanguard Aria Sovereign Triumph Prodigy Jetsetter LX Jetsetter OWNER S MANUAL