Symbols on the products, Federal law United States of America restricts this device. to sale by or on the order of a licensed healthcare General warning sign. practitioner Follow the warnings in the Instructions for. Use for parts of the unit on which this mark,Owner s Record appears. NOTE Background colour Yellow, The model and serial numbers are located at the rear Triangular band Black. Record these numbers in the space provided below Symbol Black. Refer to these numbers whenever you call upon your Sony. dealer regarding this product Consult the Instructions for Use. Follow the directions in the Instructions for, Model No Use for parts of the unit on which this mark. Serial No appears,This symbol indicates the manufacturer and.
WARNING appears next to the manufacturer s name and. To reduce the risk of fire or electric shock do not. expose this apparatus to rain or moisture This symbol indicates the European. Community representative and appears next, To avoid electrical shock do not open the to the European Community representative s. cabinet Refer servicing to qualified personnel name and address. only This symbol indicates the equipotential,terminal which brings the various parts of a. No modification of this equipment is allowed system to the same potential. For HVO 550MD, Use of controls or adjustments or performance of Do not install the appliance in a confined space such as. procedures other than those specified herein may result in book case or built in cabinet. hazardous radiation exposure, For HVO 550MD Excessive sound pressure from earphones and headphones. This HD Video Recorder is classified as a CLASS 1 can cause hearing loss. LASER PRODUCT In order to use this product safely avoid prolonged. listening at excessive sound pressure levels,For HVO 550MD For the customers in the U S A.
The use of optical instruments with this product will This equipment has been tested and found to comply with. increase eye hazard the limits for a Class B digital device pursuant to part 15. of the FCC Rules These limits are designed to provide. IMPORTANT reasonable protection against harmful interference in a. The nameplate is located on the bottom residential installation This equipment generates uses and. can radiate radio frequency energy and if not installed and. used in accordance with the instructions may cause. harmful interference to radio communications However. there is no guarantee that interference will not occur in a. particular installation If this equipment does cause. harmful interference to radio or television reception which. can be determined by turning the equipment off and on the. user is encouraged to try to correct the interference by one. or more of the following measures,Reorient or relocate the receiving antenna. Increase the separation between the equipment and, Connect the equipment into an outlet on a circuit 4 For this particular equipment all accessory equipment. different from that to which the receiver is connected connected as noted above must be connected to mains. Consult the dealer or an experienced radio TV via an additional isolation transformer conforming with. technician for help the construction requirements of IEC60601 1 and. You are cautioned that any changes or modifications not providing at least Basic Insulation. expressly approved in this manual could void your, authority to operate this equipment 5 This equipment generates uses and can radiate radio. All interface cables used to connect peripherals must be frequency energy If it is not installed and used in. shielded in order to comply with the limits for a digital accordance with the instruction manual it may cause. device pursuant to Subpart B of part 15 of FCC Rules interference to other equipment If this unit causes. interference which can be determined by unplugging. If you have any questions about this product you may call the power cord from the unit try these measures. Sony Customer Information Service Center 1 800 222 Relocate the unit with respect to the susceptible. 7669 or http www sony com equipment Plug this unit and the susceptible. equipment into different branch circuit,Declaration of Conformity. Consult your dealer According to standard IEC60601 1 2. and CISPR11 Class B Group 1,Trade Name SONY,Model HVO 500MD 550MD.
Responsible party Sony Electronics Inc,Address 16530 Via Esprillo San Diego. CA 92127 U S A,Telephone Number 858 942 2230, This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions. 1 This device may not cause harmful interference,and 2 this device must accept any interference. received including interference that may cause,undesired operation. For the customers in Canada,CAN ICES 3 B NMB 3 B, This unit has been certified according to Standard CAN.
CSA C22 2 No 60601 1,Important safeguards notices for use in the. medical environments, 1 All the equipments connected to this unit shall be. certified according to Standard IEC60601 1,IEC60950 1 IEC60065 or other IEC ISO Standards. applicable to the equipments, 2 Furthermore all configurations shall comply with the. system standard IEC60601 1 1 Everybody who, connects additional equipment to the signal input part.
or signal output part configures a medical system and. is therefore responsible that the system complies with. the requirements of the system standard IEC60601 1 1. If in doubt consult the qualified service personnel. 3 The leakage current could increase when connected to. other equipment, Important EMC notices for use in the medical environments. The HVO 500MD 550MD needs special precautions regarding EMC and needs to be installed and put into service. according to the EMC information provided in this Instructions for Use. The portable and mobile RF communications equipment such as cellular phones can affect the HVO 500MD 550MD. The use of accessories and cables other than those specified with the exception of replacement parts sold by Sony. Corporation may result in increased emissions or decreased immunity of the HVO 500MD 550MD. Guidance and manufacturer s declaration electromagnetic emissions. The HVO 500MD 550MD is intended for use in the electromagnetic environment specified below. The customer or the user of the HVO 500MD 550MD should assure that it is used in such an environment. Emission test Compliance Electromagnetic environment guidance. RF emissions The HVO 500MD 550MD uses RF energy only for its. internal function Therefore its RF emissions are very low. CISPR 11 and are not likely to cause any interference in nearby. electronic equipment, RF emissions The HVO 500MD 550MD is suitable for use in all. Class B establishments including domestic establishments and. CISPR 11 those directly connected to the public low voltage power. supply network that supplies buildings used for domestic. Harmonic emissions,Not applicable,IEC 61000 3 2,Voltage fluctuations. flicker emissions,Not applicable,IEC 61000 3 3, If the HVO 500MD 550MD should be used adjacent to or stacked with other equipment it should be observed to verify. normal operation in the configuration in which it will be used. Guidance and manufacturer s declaration electromagnetic immunity. The HVO 500MD 550MD is intended for use in the electromagnetic environment specified below The customer or the user. of the HVO 500MD 550MD should assure that it is used in such as environment. IEC 60601 test, Immunity test Compliance level Electromagnetic environment guidance.
Electrostatic 6 kV contact 6 kV contact Floors should be wood concrete or ceramic tile If floors are. discharge ESD covered with synthetic material the relative humidity should be. at least 30,IEC 61000 4 2 8 kV air 8 kV air, Electrical fast 2 kV for power Mains power quality should be that of a typical commercial or. transient burst supply lines hospital environment,IEC 61000 4 4 1 kV for input 1 kV for input. output lines output lines, Surge 1 kV line s to Not applicable Mains power quality should be that of a typical commercial or. line s hospital environment,IEC 61000 4 5 2 kV line s to. Voltage dips short 5 UT Not applicable Mains power quality should be that of a typical commercial or. interruptions and 95 dip in UT hospital environment If the user of the HVO 500MD 550MD. voltage variations for 0 5 cycle requires continued operation during power mains interruptions. on power supply it is recommended that the HVO 500MD 550MD be powered. input lines 40 UT from an uninterruptible power supply or a battery. 60 dip in UT,IEC 61000 4 11,for 5 cycles,30 dip in UT.
for 25 cycles,95 dip in UT, Power frequency 3 A m 3 A m Power frequency magnetic fields should be at least. 50 60 Hz characteristic of a typical location in a typical commercial or. magnetic field hospital environment,IEC 61000 4 8, NOTE UT is the a c mains voltage prior to application of the test level. Guidance and manufacturer s declaration electromagnetic immunity. The HVO 500MD 550MD is intended for use in the electromagnetic environment specified below The customer or the user. of the HVO 500MD 550MD should assure that it is used in such as environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance. Portable and mobile RF communications equipment, should be used no closer to any part of the HVO 500MD. 550MD including cables than the recommended,separation distance calculated from the equation. appliance to the frequency of the transmitter,Recommended separation distance.
Conducted RF 3 Vrms 3 Vrms d 1 2,IEC 61000 4 6 150 kHz to 80 MHz. Radiated RF 3 V m 3 V m d 1 2 80 MHz to 800 MHz, IEC 61000 4 3 80 MHz to 2 5 GHz d 2 3 800 MHz to 2 5 GHz. Where P is the maximum output power rating of the, transmitter in watts W according to the transmitter. manufacturer and d is the recommended separation,distance in meters m. Field strengths from fixed RF transmitters as determined. by an electromagnetic site survey a should be less than. the compliance level in each frequency range b, Interference may occur in the vicinity of equipment marked.
with following symbol, NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and. reflection from structures objects and people, a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile. radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be. considered If the measured field strength in the location in which the HVO 500MD 550MD is used exceeds the applicable. RF compliance level above the HVO 500MD 550MD should be observed to verify normal operation If abnormal. performance is observed additional measures may be necessary such as reorienting or relocating the HVO 500MD. b Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m. Recommended separation distances between portable and mobile RF communications equipment and the. HVO 500MD 550MD, The HVO 500MD 550MD is intended for use in an electromagnetic environment in which radiated RF disturbances are. controlled The customer or the user of the HVO 500MD 550MD can help prevent electromagnetic interference by. maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the. HVO 500MD 550MD as recommended below according to the maximum output power of the communications equipment. Separation distance according to frequency of transmitter. Rated maximum output power of transmitter m, W 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz. d 1 2 d 1 2 d 2 3,0 01 0 12 0 12 0 23,0 1 0 38 0 38 0 73.
1 1 2 1 2 2 3,10 3 8 3 8 7 3,100 12 12 23, For transmitters rated a maximum output power not listed above the recommended separation distance d in meters m can. be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating. of the transmitter in watts W according to the transmitter manufacturer. NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and. reflection from structures objects and people, When you dispose of the unit or accessories you must obey the laws in the relative area or country and the regulations in. the relative hospital,For the customers in Europe, This product has been manufactured by or on behalf of Sony Corporation 1 7 1 Konan Minato ku Tokyo 108 0075 Japan. Inquiries related to product compliance based on European Union legislation shall be addressed to the authorized. representative Sony Deutschland GmbH Hedelfinger Strasse 61 70327 Stuttgart Germany. For any service or guarantee matters please refer to the addresses provided in the separate service or guarantee documents. For the State of California USA only, Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate. For the customers in Taiwan only,For the customers in the U S A.
This HD Video Recorder is classified as a CLASS 1 LASER PRODUCT Caution For HVO 550MD The use of optical instruments with this product will increase eye hazard IMPORTANT The nameplate is located on the bottom CAUTION Do not install the appliance in a confined space such as book case or built in cabinet WARNING Excessive sound pressure from earphones and headphones can cause hearing loss