Clamp Meter selection chart,Job functions Applications Recommended clamp. Plant Maintenance Multiple placement potential for large 365 True rms AC Clamp Meter. Process Technician, facilities allows units to be left in place Key features. Electrician 200 A ac and A dc measurement with fixed jaw. Detachable jaw makes accessing wires and viewing the. Automation Specialist,display easier,6000 resistance measurement with continuity. Built in flashlight torch allows for easy illumination and. identification of wires, True rms to more accurately measure the actual current. even with distorted wave forms caused by noisy loads. CAT III 600 V, Residential Electrician Conduct front line troubleshooting of 373 True rms AC Clamp Meter.
general ac current systems,Electrical Contractor Key features. Verify circuit integrity and operation Measure up to 600 A ac. Commercial Electrician Measure load current ac voltage and Measure ac and dc voltage to 600 V. continuity of switches fuses and contacts True rms to more accurately measure the actual current. Feeder cables even with distorted wave forms caused by noisy loads. Check balance and loading of feeder cables Includes large backlit display ac and dc voltage. resistance continuity and capacitance,CAT IV 300 V CAT III 600 V. Electrical Contractor Basic troubleshooting of ac and dc 374 True rms AC DC Clamp Meter. General Purpose,Commercial Electrician Key features. Measure dc current in battery powered,Measure up to 600 A ac and A dc. Electric Utility Technician devices security systems etc. True rms to more accurately measure the actual current. Measure motor start up and run current, even with distorted wave forms caused by noisy loads.
Facility Maintenance Capacitance for motor start and run. Compatible with the new i2500 18 and i2500 10 iFlex. capacitors,Utility Technician, flexible current probes sold separately which expands. Check balance and loading in service,the measurement range to 2500 A ac and provides. increased display flexibility,Inrush current mode for repeatable measurement of. motor or equipment start up current,Includes large backlit display ac and dc voltage. resistance continuity MIN MAX and capacitance,CAT IV 600 V CAT III 1000 V.
Industrial Electrical Advanced troubleshooting of ac and dc 375 True rms AC DC Clamp Meter. Contractor systems,Key features, Plant Maintenance Large motors and drives and noisy. 500 mV measurement range to interface with other,electrical environments. HVAC R Specialist accessories,Motor inrush to troubleshoot current. Integrated low pass filter and state of the art,protection devices. signal processing allows for use in noisy electrical. Output of variable speed motors and drives,environments while providing stable readings.
Frequency measurement to 500 Hz with both jaw and, Compatible with the new i2500 18 and i2500 10 iFlex. flexible current probes sold separately which expands. the measurement range to 2500 A ac and provides,increased display flexibility. Measure true rms voltage capacitance resistance and. continuity,CAT IV 600 V CAT III 1000 V,Job functions Applications Recommended clamp. Industrial Electrician Fully featured model for electrical and 376 True rms AC DC Clamp Meter. industrial professionals who need to with iFlex,Plant Maintenance. conduct advanced troubleshooting of ac,and dc systems in any environment Key features.
Facility Maintenance, Measure 1000 A ac or dc with fixed jaw Measure up to 1000 A ac and A dc. to measure current in motors vaults and Inputs for 1000 V ac and V dc 60 k resistance and. bus bars continuity, 2500 A ac capability with iFlex flexible Includes the new i2500 18 and i2500 10 iFlex flexible. current probe fits around tight and current probes which expands the measurement range. awkward conductors to 2500 A ac and provides increased display flexibility. Clamp around bus bars or conductors in Narrow elongated jaw with large opening easily. service panels to measure loads and line singles out the conductor of interest. frequency in circuits True rms to more accurately measure the actual current. Industrial Electrical, even with distorted wave forms caused by noisy loads. CAT IV 600 V CAT III 1000 V, Industrial Electrician Fully featured model for electrical and 381 Remote Display True rms AC DC. industrial professionals who need to Clamp Meter with iFlex. Industrial Service conduct advanced troubleshooting of ac. Electrician,and dc systems in any environment Key features.
Measure 1000 A ac or dc with fixed jaw Wireless technology allows remote display to be carried. Plant Maintenance, to measure current in motors vaults and up to 30 ft away from point of measurement. Facility Maintenance bus bars Removable magnetic display can be conveniently. 2500 A ac capability with iFlex flexible mounted where it is easily seen. current probe fits around tight and Includes the new i2500 18 and i2500 10 iFlex flexible. awkward conductors current probes which expands the measurement range. Clamp around bus bars or conductors in to 2500 A ac and provides increased display flexibility. service panels to measure loads and line AC and dc current ac and dc voltage resistance. frequency in circuits frequency continuity capacitance min max and inrush. low pass filter, Large easy to read backlight display automatically sets. the correct measurement range,CAT IV 600 V CAT III 1000 V. Commercial Industrial Industrial troubleshooting in low current iFlex i2500 Flexible Current Probes. Electrician ac and dc applications where access is. Key features, Facility Plant Measure up to 2500 A ac current with select Fluke. Access to tight wiring in locations such as,Maintenance clamp meters.
PLC cabinets, Provides increased display flexibility and ability to. HVAC R Specialist measure awkward sized conductors. Works with frequency inrush and min max functions,7 5 mm coil diameter allows measurement in tight. Available in 10 inch and 18 inch lengths,CAT IV 600 V CAT III 1000 V. Commercial Electrical Verify circuit integrity and operation 325 True rms Clamp Meter. Contractor Measure load current ac voltage and,Resi Comm Electrical. Key features,continuity of switches fuses and contacts.
Industrial Electrical Measure up to 400 A ac and dc. Contractor Feeder Cables 0 01 A resolution in the 40 A range for more. Plant Maintenance Check balance and loading of feeder cables precise measurements. Compact form factor to make measurements easily,in tight cable compartments. Measure ac and dc voltage to 600 V,Resistance continuity temperature capacitance and. display hold functions,CAT IV 300 V CAT III 600 V,Clamp Meter selection chart cont. Job functions Applications Recommended clamp, Electrical Contractor Working on panels and branch circuits T5 1000 Electrical Tester. Comm Ind Electrical,Measure loads on a branch circuit at a.
Key features, Facility Maintenance panel including feeder cables branch. Open jaw ac current measurement to 100 A,circuits and neutrals and the continuity of. AC and dc voltage,switches fuses and contacts,Commercial Electrician T5 600 CAT III 600 V. Measure load side voltage of a breaker or,T5 1000 CAT IV 600 V CAT III 1000 V. Continuity resistance,Check if a circuit is live before beginning.
Rugged and easy to use, Facility Maintenance Measuring leakage current 360 AC Leakage Current Clamp Meter. Electrician Check insulation condition and leakage of Key features. Hospital Electrician circuits and systems Measurement of leakage current with 3 mA range and. Check for leakage in circuits and systems 1 A of resolution for accurate monitoring of insulation. Electrical Contractor utilizing filters erosion, Testing insulation on live circuits Broad range of measurement from 1 A up to 60 A for. Evaluate insulation condition on live all installation needs. circuits via leakage current measurements Advanced shielding to ensure accurate results when. where disconnection is highly inconvenient measuring near other conductors. Easy to carry pocket sized leakage current tester with. wide 40 mm 1 5 in jaw size,CAT III 300 V, Industrial Commercial Grounding and bonding resistance testing 1630 Earth Ground Clamp Meter. Maintenance Electrician Perform ground loop tests in areas where Key features. other ground resistance test techniques are Measure from 0 025 to 1500 ground loop. Utility Technician,not available resistance,Earth Ground. Electrical Contractor, Test parts of a multi grounded system Large jaw for clamping around the widest range of.
Consultant Periodically perform quick tests on system ground conductors or grounding bars. grounds as part of a regular preventative Measure ground leakage and ac load currents from. maintenance program 0 2 mA all the way up to 30 A, User defined alarm limits for rapid pass fail type. measurements,CAT III 300 V, Process Technician Measuring process control signals 773 Milliamp Process Clamp Meter. Electrician Measures 4 20 mA signals without break Key features. ing the loop Saves time and money by easily measuring 4 20 mA. Automation Specialist, Check correct operation of PLCs and control signals. Commercial Electrician, systems analog I O Detatchable miniature clamp for tight locations. Source process control signals allow for Also measure older 10 to 50 mA signal systems with. testing of 4 20 mA signals and 1 to 5 V the 100 mA range. and 0 to 10 V to test automation I O Backlit display spotlight display hold and zero reading. Advanced troubleshooting features simplify buttons. loop testing Eliminates the need for extra 4 20 mA source or. voltage equipment when troubleshooting,CAT II 300 V.
Job functions Applications Recommended clamp, Electrical and Field Measuring non linear loads 345 Power Quality Clamp Meter. Service Technician Setup and troubleshoot variable frequency Key features. drives and UPS systems Verify correct AC DC current Clamp on measurement of current up to. HVAC R Technician, operation by measuring key power quality 1400 A ac rms and 2000 A dc. Electrical Engineer, parameters CAT IV 600 V rated for use at the service entrance. Harmonic measurements Accurate in noisy environments Using low pass. Power Quality, Commercial Electrician Uncover harmonic issues that can damage filter the clamp meter performs even with distorted. or disrupt critical equipment waveforms, Facility Maintenance Data logging Identify intermittent faults by logging any.
Electrician Troubleshooting start up current issues power quality parameter for minutes or over a month. Check start up current where spurious Troubleshoot harmonics Analyze and log harmonics. Electric Utility Engineer resets or nuisance circuit breaker tripping digitally or graphically. occurs Inrush current Capture and analyze nuisance tripping. Load studies from 3 seconds to 300 seconds, Verify electrical system capacity before CAT IV 600 V CAT III 1000 V. adding loads, Industrial Service Service panel service entrance and low 355 True rms 2000 A Clamp Meter. Electrician voltage vaults Key features, In the service panel clamp around each Up to 2000 A dc 1400 A ac current measurement. High End Industrial Utility,Electrical Contractor, individual phase Good for large single or Large jaw suitable for single or multiple large. Electric Utility Technician,parallel conductors conductors.
In the service entrance clamp around CAT IV 600 V rated for maximum application versatility. Marine or Welding busbars up to 2 5 in to verify expected Inputs for 600 V ac 1000 V dc 400 K resistance and. Electrician current usage continuity, Measure current in conductors of low Low pass filter min max avg and inrush current. Facility Maintenance voltage vaults 1000 V or less Accurately measure frequency of current and voltage up. Electrician,Working with large loads to 1 kHz, Verify operation of large load service CAT IV 600 V CAT III 1000 V. panels switchgears large current DC,systems and motors. HVAC R Service Checking boilers and furnaces 902 True rms HVAC Clamp Meter. Technician Capture flue gas temperatures and perform Key features. flame rod testing Measure current up to 600 A ac and up to 200 A dc. HVAC motors and drives Measure true rms voltage capacitance resistance and. Measure start and run motor capacitors continuity, Troubleshoot compressor electrical motor Measure contact temperature with included Type K. faults temperature probe Or measure the outside temperature. Measure performance of variable frequency of a pipe with the 80PK 8 Pipe Clamp Temperature. drives Probe sold separately,CAT III 600 V,Testing electrical performance.
Measure load side and supply side current,and voltage. Measure current and voltage phase balance,on 3 phase systems. Genuine Fluke Accessories, When your job depends on every tool in your toolbox Genuine. Fluke Accessories keep you working,Clamp meter specifications. Commercial industrial Residential commercial General. electrical electrical purpose,T5 600 T5 1000 323 324 325 365.
Measurements,AC current,AC voltage,Resistance,Continuity. DC current,AC DC voltage,AC DC current,Min Max Avg. 4 20 mA 0 01 mA resolution,Temperature,Capacitance. Earth ground loop resistance,Special features,Inrush current mode. Fluke Clamp Meters Solutions for every need 355 773 more solutions inside Clamp Meter selection chart Job functions Applications Recommended clamp General Purpose Plant Maintenance Multiple placement potential for large facilities allows units to be left in place 365 True rms AC Clamp Meter Key features 200 A ac and A dc measurement with fixed jaw Detachable jaw makes accessing wires