Blatt sheet D823MGB 001,Door Drive Datum date 01 03 2004. MIDI SUPRA Stand version C 23 07 2009, Gepr ft approved WAT MZE. Operating instructions, Content Pages, 1 General information prior to information. 1 1 Description and function D823MGB 003, 1 2 Liability and guarantee D823MGB 003. 1 3 Safety precautions D823MGB 003, 1 4 Related documents D823MGB 003.
1 5 Preparation for operation D823MGB 003, 1 6 Delivery D823MGB 003. 2 Electronic assembly layout D823MGB 004, 3 Commissioning. 3 1 Power Supply D823MGB 005, 3 2 Safety circuit D823MGB 005. 3 4 Driving the doors with the elevator controller D823MGB 006. 3 5 Driving the doors by the service drive buttons D823MGB 006. 4 Adjustements always to be done, 4 1 Closing Force Adjustment D823MGB 007. 4 2 Adjustment of the speed D823MGB 007, 5 Description of LED s.
5 1 LED s Inputs D823MGB 008, 5 2 LED s Outputs D823MGB 008. 5 3 Different LED s D823MGB 008, 6 Electrical Interfaces. 6 1 Inputs D823MGB 009, 6 2 Passenger protection device input and supply D823MGB 010. 6 3 Outputs D823MGB 010, 7 DIP Switches D823MGB 011. 8 Troubleshooting, 8 1 The door does not move D823MGB 012.
8 2 The door does not reopen D823MGB 013, 8 3 Faults causing reset or switch off D823MGB 013. 8 4 Faults decreasing performance of door D823MGB 013. 8 5 Reset of coupler width D823MGB 014, 8 6 Reset of all door parameter D823MGB 014. 8 7 Connection of DC motor D823MGB 014, 9 Exchange of electronic box. 9 1 Preparation for learning of door parameters D823MGB 015. 9 2 Learning of door parameter D823MGB 016, 10 Wiring diagram. 10 1 Wiring diagram MIDI D823MGB 017, 10 2 Wiring diagram SUPRA D823MGB 018.
11 Wittur Programming Tool interface software description. 11 1 Introduction D823MGB 019, 11 2 Connecting the Wittur Programming Tool to the AMD electronic D823MGB 019. 11 3 Menu structure of Progamming Tool D823MGB 019. nderungen vorbehalten Subject to change without notice . EXCELLENCE IN COMPONENTS, Blatt sheet D823MGB 002. Door Drive Datum date 01 03 2004,MIDI SUPRA Stand version B 18 12 2008. Gepr ft approved WAT MZE,Operating instructions, 11 4 Adjusting door with Programming Tool D823MGB 020. Content Pages, 12 Default adjustment of WHD SUPRA software.
12 1 Default adjustment for MIDI drive D823MGB 026. 12 2 Default adjustment for SUPRA drive D823MGB 027. 13 Drive Belt, 13 1 Belt Tension D823MGB 028, 13 2 Belt Exchange D823MGB 029. 14 Spare Parts, 14 1 Centre opening D823MGB 030, 14 2 Side opening D823MGB 031. nderungen vorbehalten Subject to change without notice . EXCELLENCE IN COMPONENTS, Blatt sheet D823MGB 003. Door Drive Datum date 01 03 2004,MIDI SUPRA Stand version 01 03 2004. Gepr ft approved WAT MZE,Operating instructions, 1 General information prior to installation.
1 1 Description and function, WHD SUPRA car door operators are used for mid These operating instructions belong with the. and high duty elevators The Drive can move panel whole installation and must be kept in a safe place. masses up to 1200kg complete door package at all times i e drive room . weight , 1 4 Related documents, 1 2 Liability and guarantee Catalog D823CDEGB. Betriebsanleitung D823MDE, This instruction handbook is written for people. who are familiar with lift servicing and installa 1 5 Preparation for operation. tion Sufficient knowledge of lifts is essential WIT . TUR accept no responsibility for damage caused by Before installation work begins it is in your own. inproper handling or for damage caused as a interests to clarify what structural and spatial con . result of actions other than those stated in these ditions are available for installation work so that. operating instructions The WITTUR guarantee may you can see which installation procedures should . be voided if parts other than those described in must be carried out Therefore it is recommended. these instructions are installed that all circumstances be taken into consideration . and to men tally plan the installation sequence, 1 3 Safety precautions before any rash or badly planned work is carried. out Check the goods or parts for correct and full. WITTUR machine installation or repair engineers delivery upon receipt . are chiefly responsible for the safe operation of. machinery It is essential to comply with and keep Installation tools. abreast of all safety rules and legal obligations in. order to avoid personal product damage during Following tools are needed . installation maintenance and repair work T handled hexagon keys 4 mm 5 mm and 6. mm, Important safety advice and danger warnings are Screw drivers flat and crossheaded .
emphasized with the following symbols , The drive unit is preadjusted at the factory No. General danger warning other mechanical and electrical adjustments other. mentioned in this instruction are required at site . High danger risk warning i e crushing 1 6 Delivery. edge cutting edge etc , Complete preassembled drive unit Only to be. Risk of damage to machinery parts i e due stored in the original package plastic wrap The. to incorrect installation or such like components must not be unpacked until the. installation begins , Important information sign, nderungen vorbehalten Subject to change without notice . EXCELLENCE IN COMPONENTS, Blatt sheet D823MGB 004. Door Drive Datum date 01 03 2004, MIDI SUPRA Stand version 01 03 2004.
Gepr ft approved WAT MZE, Operating instructions, 2 Electronic assembly layout. X40 X10 X4,X6,X5,X9, X60,X19, X8 X16 X15 X12 X1 X2. Plug description , X1 Inputs X10 Encoder, X2 Outputs X12 Reference switch. X4 Motor X15 Photo Cell Curtain of light Receiver. X5 Battery supply option X16 Photo Cell Curtain of light Transmitter. X6 Transformer secondary winding X19 Board line in connector. X8 RS485 interface for WPT Wittur X40 Test drive buttons. Programming Tool X60 Extension plug, X9 Transformer primary winding. nderungen vorbehalten Subject to change without notice . EXCELLENCE IN COMPONENTS, Blatt sheet D823MGB 005.
Door Drive Datum date 01 03 2004,MIDI SUPRA Stand version 01 03 2004. Gepr ft approved WAT MZE,Operating instructions, 3 Commissioning. Door operators delivered directly from the factory. are pre adjusted , 3 1 Power Supply, The WHD MIDI SUPRA drive provides trans Select the recommended fuse for the nominal. formers for both different voltage ranges and voltage range see table. can supply with 120Vac or 230Vac , Nominal Supply Volage Range 120Vac 230Vac. Automatic fuse slow in control panel 6A 4A, Minimum cable required 1 5mm 1mm .
Line in supply is connected to a terminal plug, X19 . 3 2 Safety Circuit, The door contacts are prewired to a terminal. plug D2 , Safety contact ratings Min 5Vdc Max , 250Vac 2A. nderungen vorbehalten Subject to change without notice . EXCELLENCE IN COMPONENTS, Blatt sheet D823MGB 006. Door Drive Datum date 01 03 2004,MIDI SUPRA Stand version C 23 07 2009.
Gepr ft approved WAT MZE,Operating instructions, 3 3 Driving the doors with the eleva 3 4 Driving the doors by the service. tor controller drive buttons, Connect the signals from the elevator control The Test Buttons only work when the Test but . ler to connector X1 and X2 of the door opera ton operation switch S1 1 is active . tor , Check that the door is moving open and close. Refer to the project delivery documents for the when the test buttons are pressed . wiring diagram between the elevator controller, and door operator see also connection diagram In this mode of operation the re opening of the. in chapter 9 MIDI or chapter 10 SUPRA door by a safety device is not activated ena . bles the adjustment of the closing force , Check if Test Button operation switch is OFF.
S1 1 , If the door is not at the reference switch near. by close end in power up and CLOSE is active, connected with COMMON it will move at low. speed as long as the reference close end posi , tion is found . After finding the reference switch the door, drive will start with the next OPEN command in. direction open with normal speed drive until, the mechanical end is found .
Then the door will drive with normal speed in, both directions . Check that the safety devices open button , photo cells and close force limiter reopen the. door see DIP switch description , According to the DIP Switch adjustment S1 2 . the door is reopend by the elevator control or, automatic by the door . nderungen vorbehalten Subject to change without notice . EXCELLENCE IN COMPONENTS, Blatt sheet D823MGB 007.
Door Drive Datum date 01 03 2004,MIDI SUPRA Stand version B 18 12 2008. Gepr ft approved WAT MZE,Operating instructions, 4 Adjustments always to be done. 4 1 Closing Force Adjustment, An adjustment of too high closing force Drive the door with the close button or close. may cause serious injury to passengers The command to the close direction The Test. max allowed force can be found in the Buttons only function when the Test button. code valid for your country EN81 max operation switch S1 1 is activated . 150N , The close command should be applied for less. The adjustment must be done by use of a than 10sec period s than remove the close. force measuring device command for a short time before continue the. adjustment procedure , Do not attempt to measure the force of a.
moving door stop it first to avoid damage Adjust the closing force according codes using. of the force measuring device potentiometer CLOSE FORCE The Closing Force. will increase by turning the potentiometer, Open and close the door manually and check clockwise . that there is no mechanical obstruction , Put a force measuring device between the door. panels center opening or between door panel, and slam post side opening . 4 2 Adjustment of the speed, The drive electronic offer to select one out of. four different speed levels for handicap eleva , For centre opening the measuring device tors or other purpose .
will show half of the actual close force For, side opening the measuring device will Look at DIP SWITCH description chapter 7 . show the actual close force , nderungen vorbehalten Subject to change without notice . EXCELLENCE IN COMPONENTS, Blatt sheet D823MGB 008. Door Drive Datum date 01 03 2004,MIDI SUPRA Stand version C 23 07 2009. Gepr ft approved WAT MZE,Operating instructions, 5 Description of LED s.
5 1 LED s Inputs, Name LED leuchtet wenn, I1 Input 1 is connected to COM. I2 Input 2 is connected to COM, I3 Input 3 is connected to COM. I4 Input 4 is connected to COM, I5 Input 5 is connected to COM. IPD Input Passenger Protection Device Photo cell . 5 2 LED s Outputs, Name LED illuminated if, O1 Output 1 relay is operated. O2 Output 2 relay is operated, O3 Output 3 relay is operated.
O4 Output 4 relay is operated, 5 3 Different LED s. Name LED illuminated if, POWER the power supply is switched on. WDOG the microcontroller does not work, STATE Light during start up and learning. Flashes if a error is detected, 1x Motor encoder fault. 3x internal fault, 4x abnormal operation, 5x learning error.
Details see page 14 item 8 3, Off normal operation. REFSW the door is in close end switch area, VOLTAGE SEL 120VAC supply voltage selected. 120VAC, nderungen vorbehalten Subject to change without notice . EXCELLENCE IN COMPONENTS, Blatt sheet D823MGB 009. Door Drive Datum date 01 03 2004,MIDI SUPRA Stand version B 18 12 2008.
Gepr ft approved WAT MZE,Operating instructions, 6 Electrical Interfaces. 6 1 Inputs, The Inputs are activated if they are switched at. COM , Name of the ter , Terminal Symbol Explanation. minal, COM COM COMMON Common line for I 1 4, This command will drive the door in open direction until. the open position is reached Depending on the setting of. I1 OPEN, DIP switch S1 8 the door is kept open by motor torque.
also without command , This command will drive the door in close direction until. close position is reached and coupler is opened Depending. I2 CLOSE, on the setting of DIP switch S1 8 the door is kept closed. by motor torque also without command, Nudging input puts the door to slow speed drive in close. I3 NDG NUDGING direction Smoke sensitive devices like photo cell or light. barrier Input IPD will be ignored , By setting this input a higher speed can be selected This. I4 RSH HIGH SPEED, input is active only when DIP switch S1 6 is switched OFF .
The door opens if this input is set during the door is supp . I5 EO EMERCENY OPEN lied by a emergency battery terminal X5 BATT and no line. supply is available any more , nderungen vorbehalten Subject to change without notice . EXCELLENCE IN COMPONENTS, Blatt sheet D823MGB 010. Door Drive Datum date 01 03 2004,MIDI SUPRA Stand version B 18 12 2008. Gepr ft approved WAT MZE,Operating instructions, 6 2 Passenger protection device input. and supply, The Input is activated if put at GND .
ler to connector X1 and X2 of the door opera tor Refer to the project delivery documents for the wiring diagram between the elevator controller and door oper ator see also connection diagr am in chapter 9 gt MIDI or chapter 10 gt SUPRA Check if Test Button operation switch is OFF S1 1 If the door is not at the reference switch near