Elite Electronic Engineering,Military FCC,Commercial CE Mark. Aviation International,Automotive,Truck Ag Environmental. Construction Stress,Elite Electronic Engineering,Military Commercial Aviation. RS testing 200V m to 40GHz,HIRF CAT F ALSE CAT G mode tuned. Lightning DO 160E WF1 5 Level 5,FCC CE Mark,3m chamber.
TCB CAB Certification Services,Environmental,Full environmental stress test laboratory. Large Vibration Tables,CE Marking Compliance,Requirements Overview for EMC Safety. European Conformity Assessment Process,EMC Requirements. Safety Requirements,Documentation Requirements,Gray Areas. Typical Costs Timing,Informational Sites,Global Compliance Requirements.
RF Interference Digital Devices,FCC 47CFR Part 15B. Industry Canada ICES 003,OSHA Local Authorities,Industry Canada Provincial Authorities. European Commission,Defines EHSR in Directives,EMC Directive Low Voltage Directive. Machine Safety Directive,R TTE Directive,Defines Standards in Official Journal. CEN CENELC,IEC CISPR ISO ETSI,Asia Latin America,Low Voltage Directive.
Principal Elements of the Safety Objectives for Electrical Equipment Designed. For Use within Certain Voltage Limits, 2 Protection against hazards arising from the electrical equipment. Measures of a technical nature should be prescribed in accordance with point 1 in order to ensure. a that persons and domestic animals are adequately protected against the danger of physical injury or other harm. which might be caused by direct or indirect contact. b that temperatures arcs or radiation which would cause a danger are not produced. c that persons domestic animals and property are adequately protected against non electrical dangers caused by the. electrical equipment which are revealed by experience. d that the insulation must be suitable for foreseeable conditions. European Union Compliance,EU 27 Countries Luxembourg. Netherlands,EFTA 4 Countries Denmark,Ireland Ireland. Iceland Norway Licht Switz United Kingdom,PECA Protocols to the Europe Spain. Agreements on Conformity Austria,Assessment PECAs Sweden.
Hungary Czech Republic Lithuania Cyprus, Latvia Slovenia the Slovak Republic Czech Republic. and Estonia Bulgaria and Romania to,follow Latvia,European Union Compliance. The need for CE Marking,New Approach Directives, Eliminate differences in laws therefore remove non tariff barriers to trade. Prescribe the Essential Health Safety and Performance Requirements. Member states transpose directives and harmonized standards into their. national requirements,Absence of third party intervention. Manufacturer Self Declaration,Voluntary Use of Standards.
CE Label as the indication of compliance,Some national exceptions. CE Mark Conformity Assessment Process,Due Diligence. Identify Conformity,Select appropriate directive,Assessment Plan. Directives Select appropriate standard,Standards Identify configuration of apparatus. Documentation,Develop Test Plan for EMC, Test or analysis Test to harmonized standard non harmonized standard.
perform review analysis,Compile Technical Construction File. Prepare DOC,Manufacturer prepares signs DOC,Apply CE Mark Manufacturer affixes the CE label. New Approach Directives,93 42 EEC Medical devices General. 90 396 EEC Appliances burning gaseous fuels, Cableway installations designed to 98 79 EC Medical devices In vitro diagnostic. 2000 9 EC carry persons,New hot water boilers fired with liquid or.
89 106 EEC Construction products 92 42 EEC gaseous fluids efficiency requirements. 2004 108 EC Electromagnetic compatibility 90 384 EEC Non automatic weighing instruments. Equipment and protective systems, in potentially explosive 94 62 EC Packaging and packaging waste. 94 9 EC atmospheres, 93 15 EEC Explosives for civil uses 89 686 EEC Personal protective equipment. 95 16 EC Lifts 97 23 EC Pressure equipment,Radio and telecommunications terminal. 2006 95 EC Low voltage equipment 1999 5 EC equipment. 98 37 EC Machinery safety 94 25 EC Recreational craft. 2004 22 EEC Measuring instruments 87 404 EEC Simple pressure vessels. 90 385 EEC Medical devices Active implantable 88 378 EEC Toys safety. Which Directives Apply,Specific Directives,General Directives. Explicit exclusions in EMC Directive, Aeronautical products parts and appliances covered by 1592 2002 216 2008.
Radio Transmitters covered by 1999 5 EC, Amateur radio equipment non commercially available. Exclusions for equipment covered by other specific directives. Medical Devices,Motor Vehicles,Agricultural and Forestry Tractors. e mark type approvals,Applicable Directives,EMC Directive 2004 108 EC. Digital devices motors,Low Voltage Directive 2006 95 EC. 50VAC 1000VAC,75VDC 1500VDC,Machine Safety Directive 98 37 EC 2006 42 EC.
Primarily mechanical systems,Moving entanglement sharps hazards. Each Directive above has a Guide,Applicability of EMC Directive. Excluded from the EMC Directive,No Contains electrical. electronic parts,Yes Product families,Yes Covered by other. Directives,Yes Inherently benign,Applicability of EMC Directive.
Components or Finished,Combination of finished Installation. Sub assemblies Appliance,appliances made,Yes Yes commercially available as. a single functional unit,Excluded from the EMC Directive. Intended for,incorporation Yes,Yes No Intended for the. By the end user,Applicability of EMC Directive,Intended for.
No incorporation Yes,into given fixed,installation. commercially,Manufacturers Choice,Fixed Installation. Provisions for apparatus intended for incorporation into a given. CE Marking 2004 108 EC fixed installation and otherwise not commercially available. Documentation includes, Identification of fixed installation EMC characteristics. Precautions for incorporation into the installation. EN 61326 1 2006 1 Scope This part of IEC 61326 specifies requirements for immunity and emissions regarding electromagnetic compatibility EMC for electrical equipment operating from a supply or battery of less than 1 000 V a c or 1 500 V d c or from the circuit being measured