Outdoor Unit RXM M9,TABLE OF CONTENTS,1 Features 2. 2 Specifications 3,Capacity and Power input 3,Capacity and Power input 4. Capacity and Power input 4,Capacity and Power input 5. Capacity and Power input 6,Capacity and Power input 6. Capacity and Power input 7,Technical Specifications 8.
Electrical Specifications 9,3 Electrical data 10,4 Capacity tables 12. Cooling Heating Capacity Tables 12,5 Dimensional drawings 25. 6 Centre of gravity 26,7 Piping diagrams 28,8 Wiring diagrams 30. Wiring Diagrams Single Phase 30,9 Sound data 32,Sound Pressure Spectrum 32. 10 Operation range 35,Split Sky Air RXM M9 1,Outdoor Unit RXM M9.
1 Features, t y i k n S U r o9 toM id ltM pXu RSO Seasonal efficiency values up to A Outdoor units are fitted with a swing compressor renowned for its low. noise and high energy efficiency, Choosing for an R 32 product reduces the environmental impact with. 68 compared to R 410A and leads directly to lower energy Outdoor units for pair application. consumption thanks to its high energy efficiency Anti corrosion treated outdoor heat exchanger fin. Daikin outdoor units are neat sturdy and can easily be mounted on a. roof or terrace or simply placed against an outside wall. Outdoor unit,silent operation,2 Split Sky Air RXM M9. Outdoor Unit RXM M9,2 Specifications,2 1 Capacity and Power input. Indoor unit FTXM20M2V1 FTXM25M2V1 FTXM35M2V1 FTXM42M2V1 FTXM50M2V1 FTXM60M2V1. B B B B B B, Outdoor unit RXM20M3V1B RXM25M3V1B RXM35M3V1B RXM42M3V1B RXM50M3V1B RXM60M3V1B.
9 9 9 9 9 9,Cooling capacity Min kW 1 3 1 4 1 70 1 90 2. Btu h 4 400 0 4 800 0 5 800 6 500,kcal h 1 120 0 1 200 0 1 460 1 700. Nom kW 2 0 2 5 3 4 4 20 5 00 6 00, Btu h 6 800 0 8 500 0 11 600 0 14 300 17 100 20 500. kcal h 1 720 0 2 150 0 2 920 0 3 610 4 300 5 160,Max kW 2 6 3 2 4 0 5 00 5 30 6 70. Btu h 8 900 0 11 000 0 13 600 0 17 100 18 100 22 900. kcal h 2 240 0 2 750 0 3 440 0 4 300 4 560 5 800,Heating capacity Min kW 1 30 1 40 1 70.
Btu h 4 400 0 4 800 0 5 800,kcal h 1 120 0 1 200 0 1 460 1 500. Nom kW 2 50 2 80 4 00 5 40 5 80 7 00, Btu h 8 500 0 9 500 0 13 600 0 18 400 19 800 23 900. kcal h 2 150 0 2 400 0 3 440 0 4 640 4 990 6 020,Max kW 3 50 4 70 5 20 6 00 6 50 8 00. Btu h 11 900 0 16 000 0 17 700 0 20 500 22 200 27 300. kcal h 3 010 0 4 040 0 4 470 0 5 160 5 590 6 900,Power input Cooling Min kW 0 27 0 31. Nom kW 0 44 0 56 0 80 1 12 1 36 1 77,Max kW 0 63 0 78 1 04.
Heating Min kW 0 24 0 32,Nom kW 0 50 0 56 0 99 1 31 1 45 1 94. Max kW 0 91 1 22 1 67, Seasonal efficiency Cooling Energy efficiency class A A. according to Pdesign kW 2 00 2 50 3 40 4 20 5 00 6 00. EN14825 SEER 8 53 8 52 8 51 7 50 7 33 6 90,Annual energy kWh 83 103 140 196 239 304. consumption,Heating Average Energy efficiency class A A A. climate Pdesign kW 2 30 2 40 2 50 4 00 4 60,SCOP A 5 10 4 60 4 30.
Annual energy kWh 632 659 686 1 216 1 400 1 496,consumption. Current Nominal running Cooling A 2 1 2 6 4 4 5 11 6 26 7 90. current RLA 50Hz Heating A 2 2 2 5 4 8 5 93 6 56 8 50. Eurovent Sound power level Cooling Nom dBA 59 61 62 63. Sound power level Cooling Nom dBA 57 60 59 60,Piping length Cooling Measur m 5 0. Nominal efficiency EER 4 57 4 50 4 23 3 75 3 68 3 39. COP 5 00 4 04 4 12 4 00 3 61,Annual energy consumption kWh 220 280 400. Energy labeling Cooling A,Directive Heating A,See separate drawing for electrical data. Nominal cooling capacities are based on indoor temperature 27 CDB 19 CWB outdoor temperature 35 CDB equivalent refrigerant piping 5m level difference 0m. Nominal heating capacities are based on indoor temperature 20 CDB outdoor temperature 7 CDB 6 CWB equivalent refrigerant piping 5m level difference 0m. Split Sky Air RXM M9 3,Outdoor Unit RXM M9,2 Specifications.
2 2 Capacity and Power input FDXM25F3 RXM25M9 FDXM35F3 RXM35M9 FDXM50F3 RXM50M9 FDXM60F3 RXM60M9. Indoor unit FDXM25F3V1B FDXM35F3V1B FDXM25F3V1B FDXM60F3V1B. Outdoor unit RXM25M3V1B9 RXM35M3V1B9 RXM50M3V1B9 RXM60M3V1B9. Cooling capacity Nom kW 2 40 3 40 5 00 6 00,Btu h 8 189 11 601 17 061 20 473. 2 kcal h 2 064 2 923 4 299 5 159,Heating capacity Nom kW 3 20 4 00 5 80 7 00. Btu h 10 919 13 649 19 790 23 885,kcal h 2 752 3 439 4 987 6 019. Power input Cooling Nom kW 0 64 1 14 1 63 2 05,Heating Nom kW 0 80 1 15 1 87 2 18. Seasonal efficiency Cooling Energy efficiency class A A A A. according to Pdesign kW 2 40 3 40 5 00 6 00,EN14825 SEER 5 68 5 26 5 77 5 56.
Annual energy kWh 148 226 303 315,consumption,Heating Average Energy efficiency class A A. climate Pdesign kW 2 60 2 90 4 00 4 60,SCOP A 4 24 3 88 3 93 3 80. Annual energy kWh 858 1 046 1 424 1 693,consumption. Eurovent Sound power level Cooling Nom dBA 59 61 62 63. Sound power level Cooling Nom dBA 53 55 56,Piping length Cooling Measur m 5 0. Nominal efficiency EER 3 77 2 98 3 06 2 93,COP 4 00 3 48 3 10 3 21.
Annual energy consumption kWh 318 1 570 1 816 1 1 024 1. Energy labeling Cooling A C B C,Directive Heating A B D C. 1 Nominal heating capacities are based on indoor temperature 20 CDB outdoor temperature 7 CDB 6 CWB equivalent refrigerant piping 5m level difference 0m. See separate drawing for electrical data,See separate drawing for operation range. Nominal cooling capacities are based on indoor temperature 27 CDB 19 CWB outdoor temperature 35 CDB equivalent refrigerant piping 5m level difference 0m. 2 3 Capacity and Power input FVXM25F RXM25M9 FVXM35F RXM35M9 FVXM50F RXM50M9. Indoor unit FVXM25FV1B FVXM35FV1B FVXM50FV1B,Outdoor unit RXM25M3V1B9 RXM35M3V1B9 RXM50M3V1B9. Cooling capacity Nom kW 2 50 3 50 5 00,Btu h 8 530 11 943 17 061. kcal h 2 150 3 009 4 299,Heating capacity Nom kW 3 40 4 50 5 80.
Btu h 11 601 15 355 19 790,kcal h 2 923 3 869 4 987. Power input Cooling Nom kW 0 60 1 09 1 55,Heating Nom kW 0 77 1 19 1 60. 4 Split Sky Air RXM M9,Outdoor Unit RXM M9,2 Specifications. 2 3 Capacity and Power input, Seasonal efficiency Cooling Energy efficiency class. FVXM25F RXM25M9 FVXM35F RXM35M9,FVXM50F RXM50M9,according to Pdesign kW 2 50 3 50 5 00.
EN14825 SEER 7 20 6 43 6 80,Annual energy kWh 120 190 257. consumption,Heating Average Energy efficiency class A. climate Pdesign kW 2 40 2 90 4 20,SCOP A 4 56 4 00. Annual energy kWh 737 1 015 1 471,consumption, Eurovent Sound power level Cooling Nom dBA 59 61 62. Sound power level Cooling Nom dBA 52 57,Piping length Cooling Measur m 5 0.
Nominal efficiency EER 4 20 3 21 3 23,COP 4 42 3 78 3 63. Annual energy consumption kWh 298 545 773,Energy labeling Cooling A. Directive Heating A,See separate drawing for electrical data. See separate drawing for operation range, Nominal cooling capacities are based on indoor temperature 27 CDB 19 CWB outdoor temperature 35 CDB equivalent refrigerant piping 5m level difference 0m. Nominal heating capacities are based on indoor temperature 20 CDB outdoor temperature 7 CDB 6 CWB equivalent refrigerant piping 5m level difference 0m. 2 4 Capacity and Power input FFA25A RXM25M9 FFA35A RXM35M9 FFA50A RXM50M9 FFA60A RXM60M9. Indoor unit FFA25A2VEB FFA35A2VEB FFA50A2VEB FFA60A2VEB. Outdoor unit RXM25M3V1B9 RXM35M3V1B9 RXM50M3V1B9 RXM60M3V1B9. Cooling capacity Nom kW 2 50 3 40 5 00 5 70,Btu h 8 530 11 601 17 061 19 449.
kcal h 2 150 2 923 4 299 4 901,Heating capacity Nom kW 3 20 4 20 5 80 7 00. Btu h 10 919 14 331 19 790 23 885,kcal h 2 752 3 611 4 987 6 019. Power input Cooling Nom kW 0 55 0 89 1 54 1 87,Heating Nom kW 0 82 1 20 1 66 2 05. Seasonal efficiency Cooling Energy efficiency class A A. according to Pdesign kW 2 50 3 40 5 00 5 70,EN14825 SEER 6 17 6 38 5 98 5 76. Annual energy kWh 142 186 292 347,consumption,Heating Average Energy efficiency class A A A.
climate Pdesign kW 2 31 3 10 3 84 3 96,SCOP A 4 24 4 10 3 90 4 04. Annual energy kWh 762 1 058 1 377 1 372,consumption. Eurovent Sound power level Cooling Nom dBA 59 61 62 63. Sound power level Cooling Nom dBA 48 51 56 60,Piping length Cooling Measur m 5 0. Split Sky Air RXM M9 5,Outdoor Unit RXM M9,2 Specifications. 2 4 Capacity and Power input FFA25A RXM25M9 FFA35A RXM35M9 FFA50A RXM50M9 FFA60A RXM60M9. Nominal efficiency EER 4 57 3 81 3 24 3 05,COP 3 90 3 50 3 49 3 41.
Annual energy consumption kWh 273 1 446 1 771 1 934 1. Energy labeling Cooling A B,Directive Heating A B, 1 Nominal heating capacities are based on indoor temperature 20 CDB outdoor temperature 7 CDB 6 CWB equivalent refrigerant piping 5m level difference 0m. See separate drawing for electrical data,See separate drawing for operation range. Nominal cooling capacities are based on indoor temperature 27 CDB 19 CWB outdoor temperature 35 CDB equivalent refrigerant piping 5m level difference 0m. 2 5 Capacity and Power input FBA35A RXM35M9 FBA50A RXM50M9 FBA60A RXM60M9. Indoor unit FBA35A2VEB FBA50A2VEB FBA60A2VEB,Outdoor unit RXM35M3V1B9 RXM50M3V1B9 RXM60M3V1B9. Cooling capacity Nom kW 3 40 5 00 5 70,Btu h 11 601 17 061 19 449. kcal h 2 923 4 299 4 901,Heating capacity Nom kW 4 00 5 50 7 00.
Btu h 13 649 18 767 23 885,kcal h 3 439 4 729 6 019. Power input Cooling Nom kW 0 85 1 41 1 64,Heating Nom kW 1 00 1 44 1 89. Seasonal efficiency Cooling Energy efficiency class A A. according to Pdesign kW 3 40 5 00 5 70,EN14825 SEER 6 23 6 27 5 91. Annual energy kWh 191 279 337,consumption,Heating Average Energy efficiency class A. climate Pdesign kW 2 90 4 40 4 60,SCOP A 4 07 4 06 4 01.
Annual energy kWh 996 1 517 1 607,consumption, Eurovent Sound power level Cooling Nom dBA 61 62 63. Sound power level Cooling Nom dBA 60 56,Piping length Cooling Measur m 5 0. Nominal efficiency EER 4 02 3 55 3 48,COP 4 02 3 83 3 71. Annual energy consumption kWh 423 704 818,Energy labeling Cooling A. Directive Heating A,See separate drawing for electrical data.
See separate drawing for operation range, Nominal cooling capacities are based on indoor temperature 27 CDB 19 CWB outdoor temperature 35 CDB equivalent refrigerant piping 5m level difference 0m. Nominal heating capacities are based on indoor temperature 20 CDB outdoor temperature 7 CDB 6 CWB equivalent refrigerant piping 5m level difference 0m. 2 6 Capacity and Power input FCAG35A RXM35M9 FCAG50A RXM50M9 FCAG60A RXM60M9. Indoor unit FCAG35AVEB FCAG50AVEB FCAG60AVEB,Outdoor unit RXM35M3V1B9 RXM50M3V1B9 RXM60M3V1B9. 6 Split Sky Air RXM M9,Outdoor Unit RXM M9,2 Specifications. 2 6 Capacity and Power input,Cooling capacity Nom kW. FCAG35A RXM35M9,FCAG50A RXM50M9,FCAG60A RXM60M9,Btu h 11 943 17 061 19 449.
kcal h 3 009 4 299 4 901,Heating capacity Nom kW 4 20 6 00 7 00. Btu h 14 331 20 473 23 885,kcal h 3 611 5 159 6 019. Power input Cooling Nom kW 0 94 1 39 1 72,Heating Nom kW 1 11 1 62 2 07. Seasonal efficiency Cooling Energy efficiency class A. according to Pdesign kW 3 50 5 00 5 70,EN14825 SEER 6 35 6 54 6 40. Annual energy kWh 193 266 312,consumption,Heating Average Energy efficiency class A A.
climate Pdesign kW 3 32 4 36 4 71,SCOP A 4 90 4 30 4 20. Annual energy kWh 948 1 419 1 569,consumption, Eurovent Sound power level Cooling Nom dBA 61 62 63. Sound power level Cooling Nom dBA 49 51,Piping length Cooling Measur m 5 0. Nominal efficiency EER 3 72 3 58 3 31,COP 3 77 3 70 3 38. Annual energy consumption kWh 471 697 862,Energy labeling Cooling A.
Directive Heating A C,See separate drawing for electrical data. See separate drawing for operation range, Nominal cooling capacities are based on indoor temperature 27 CDB 19 CWB outdoor temperature 35 CDB equivalent refrigerant piping 5m level difference 0m. Nominal heating capacities are based on indoor temperature 20 CDB outdoor temperature 7 CDB 6 CWB equivalent refrigerant piping 5m level difference 0m. 2 7 Capacity and Power input FHA35A RXM35M9 FHA50A RXM50M9 FHA60A RXM60M9. Indoor unit FHA35AVEB FHA50AVEB FHA60AVEB,Outdoor unit RXM35M3V1B9 RXM50M3V1B9 RXM60M3V1B9. Cooling capacity Nom kW 3 40 5 00 5 70,Btu h 11 601 17 061 19 449. kcal h 2 923 4 299 4 901,Heating capacity Nom kW 4 00 6 00 7 20.
Btu h 13 649 20 473 24 567,kcal h 3 439 5 159 6 191. Power input Cooling Nom kW 0 91 1 56 1 73,Heating Nom kW 0 98 1 79 2 17. Split Sky Air RXM M9 7,Outdoor Unit RXM M9,2 Specifications. 2 7 Capacity and Power input FHA35A RXM35M9 FHA50A RXM50M9 FHA60A RXM60M9. Seasonal efficiency Cooling Energy efficiency class A A. according to Pdesign kW 3 40 5 00 5 70,EN14825 SEER 6 24 5 92 6 08. Annual energy kWh 191 295 328,consumption,2 Heating Average Energy efficiency class A A.
climate Pdesign kW 3 10 4 35 4 71,SCOP A 4 43 3 86 3 87. Annual energy kWh 979 1 578 1 704,consumption, Eurovent Sound power level Cooling Nom dBA 61 62 63. Sound power level Cooling Nom dBA 53 54,Piping length Cooling Measur m 5 0. Nominal efficiency EER 3 73 3 21 3 29,COP 4 08 3 35 3 32. Annual energy consumption kWh 456 1 780 1 867 1,Energy labeling Cooling A B A.
Directive Heating A C, 1 Nominal heating capacities are based on indoor temperature 20 CDB outdoor temperature 7 CDB 6 CWB equivalent refrigerant piping 5m level difference 0m. See separate drawing for electrical data,See separate drawing for operation range. Nominal cooling capacities are based on indoor temperature 27 CDB 19 CWB outdoor temperature 35 CDB equivalent refrigerant piping 5m level difference 0m. 6 Split Sky Air RXM M9 2 Specifications Notes 1 Nominal heating capacities are based on indoor temperature 20 CDB outdoor temperature 7 CDB 6 CWB equivalent refrigerant piping 5m level difference 0m See separate drawing for electrical data See separate drawing for operation range Nominal cooling capacities are based on indoor temperature 27 CDB 19 CWB outdoor